FLUKE-360 Fluke, FLUKE-360 Datasheet - Page 2

AC Leakage Current Clamp Meter

FLUKE-360

Manufacturer Part Number
FLUKE-360
Description
AC Leakage Current Clamp Meter
Manufacturer
Fluke
Type
Current Clampr
Datasheets

Specifications of FLUKE-360

Dmm Type
Clamp
Current Measuring Range Ac
3mA To 60A
Dmm Response Type
Mean Value
Dmm Functions
AC Current
Ranging
Auto
Display Count
3200
Battery Life
Approx. 90 hours (when continuously used)
Battery Type
1 × 3 V Lithium battery (button cell) CR2032
Conductor Size
Measureable up to 40 mm
Current Range
3 mA to 60 A
Cycle Time
2 times/second (Digital display), 12 times/second (Bar-graph display)
Dimensions
6.9" × 2.8" × 1.0"
Display
Bar-graph display: 32 segments, LCD ,3200 counts
Temperature Coefficient
0°C to 50°C, 80 % RH or less (no condensation)
Voltage, Rating
Circuit ≤300 VRMS
Weight
200 g
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Special Features
IEC 61010 and EMC Conformance
IEC 61010 safety features including a tactile barrier and 
special jaw design provide the user with confidence 
when making measurements in hazardous voltage areas. 
Conformance to EMC standards ensures high reliability 
through reduced susceptibility to electromagnetic interference. 
  The Fluke 360 also meets the latest safety standard 
VDE0404-4 and the new VDE0702 requirements. 
Specifications at 23 ± 5 °C. 80 % R
Accuracy: ± (% rdg + dgt) = ± (% readout + value of least significant digit)  
AC Current Measurement
Mean value detection and rms-value calibration.  
Accuracy specified at 50/60 Hz  
Frequency range 15 Hz to 150 Hz 
2  Fluke Corporation     Fluke 360 AC Leakage Current Clamp Meter
General Specification
Electrical Specification
Method of detection
Display
Measurement cycle
Range switching
Ambient temperature and humidity
Temperature coefficient
Influence of external magnetic field
Influence of conductor position
Circuit voltage
Safety standard
Withstanding voltage
Battery type
Battery life
Auto power-off
Diameter of measurable conductor
Weight
Dimension
Operating altitude
Measuring range
30 mA
3 mA 
30 A
60 A
Resolution
0.001 mA 
0.01 mA
0.01 A
0.1 A
H
 max 
5 % + 5 (50~60 A) 
1 % + 5 (0~50 A) 
Accuracy
1 % + 5
Mean value 
Digital display: 3200 counts
Bar-graph display: 32 segments, LCD
2 times/second (Digital display), 12 times/second (Bar-graph display) 
Auto-range 
0 °C to 50 °C, 80 % R
0.05 % of range/°C or less (within the ranges of 0 °C to 18 °C and  
28 °C to 50 °C for measurement of 0-50 A) 
0.0005 % typical 1 (on current value of adjacent cable) 
Within accuracy 
≤ 300 Vrms 
EN 61010-1, EN 61010-2-032. 300 V CAT II, Pollution Degree 2 
3.7 kV ac for one minute 
1 x 3 V Lithium battery (button cell) CR2032
Approx. 90 hours (when continuously used) 
Approx. 10 minutes 
40 mm max. 
200 g (441 lb)
176 mm x 70 mm x 25 mm (6.9 in x 2.8 in x 1 in)
2000 m (6,562 ft)
Max Permissible current
H
 or less (no condensation) 
High Accuracy
Advanced jaw design means that the Fluke 360 accuracy 
is little affected by external magnetic fields even at low 
currents. Typical external current rejection is 200,000:1.
60 A rms
Fluke. Keeping your world
Fluke Corporation 
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V. 
PO Box 1186, 5602 BD  
Eindhoven, The Netherlands
For more information call: 
In the U.S.A. (800) 443-5853 or  
Fax (425) 446-5116 
In Europe/M-East/Africa +31 (0) 40 2675 200 or  
Fax +31 (0) 40 2675 222 
In Canada (800)-36-FLUKE or  
Fax (905) 890-6866 
From other countries +1 (425) 446-5500 or  
Fax +1 (425) 446-5116 
Web access: http://www.fluke.com
©2006 Fluke Corporation. All rights reserved.  
Specifications subject to change without notice.  
Printed in U.S.A. 12/2006 2791021 D-EN-N Rev A
up and running.™