U1272A AGILENT TECHNOLOGIES, U1272A Datasheet - Page 9

DIGITAL MULTIMETER, HANDHELD

U1272A

Manufacturer Part Number
U1272A
Description
DIGITAL MULTIMETER, HANDHELD
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of U1272A

Dmm Type
Handheld
Voltage Measuring Range Dc
30mV To 1000V
Voltage Measuring Range Ac
30mV To 1000V
Current Measuring Range Dc
300µA To 10A
Current Measuring Range Ac
300µA To 10A
Lead Free Status / RoHS Status
na
3.
4.
AC specifications for U1271A
1. Notes for voltage specifications:
2. Notes for current specifications:
True RMS AC
True RMS AC
Voltage
Function
Function
Current
Notes for current specifications:
Notes for diode specifications:
Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse
Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse
Specification for 300 mA range: 440 mA continuous.
Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals >10 to 20 A for 30 seconds
maximum. After measuring currents >10 A, cool down the multimeter for twice the duration of the mea-sured time before proceeding with low
current measurements.
Overload protection: 1000 Vrms for short circuits with <0.3 A current.
Built-in buzzer beeps continuously when the voltage measured is less than 50 mV and beeps once for forward-biased di-ode or semiconductor
junctions measured between 0.3 V and 0.8 V (0.3 V ≤ reading ≤ 0.8 V).
Open voltage for diode: <+3.3 V DC
Open voltage for Auto diode: <+2.5 V DC and > -1.0 V DC
Overload protection: 1000 Vrms. For millivolt measurements, 1000 Vrms for short circuits with <0.3 A current.
Input impedance: 10 MΩ (nominal) in parallel with <100 pF.
Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse
Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse
Specification for 300 mA range: 440 mA continuous.
Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals >10 to 20 A for 30 seconds
maximum. After measuring currents >10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low
current measurements.
[2]
[1]
Range
300 mV
enabled, applicable for
1000 V
all voltage ranges and
3000 µA
300 V
Range
300 mA
300 µA
LPF (low pass fi lter)
30 V
30 mA
3 V
10 A
3A
resolution
Resolution
0.0001 V
0.01 mV
Resolution
0.001 V
0.01 V
0.1 V
0.001 mA
0.0001 A
0.01 mA
0.01 µA
0.001 A
0.1 µA
45 Hz to 65 Hz
Accuracy ± (% of reading + counts of least significant digit)
counts of least significant digit)
0.7 + 20
0.7 + 20
0.7 + 20
0.7 + 20
0.7 + 20
0.7 + 20
Accuracy ± (% of reading +
45 Hz to 2 kHz
9
0.9 + 25
0.9 + 25
0.9 + 25
0.9 + 25
1.0 + 25
1.0 + 25
1.0 + 25 @ <200 Hz
5.0 + 25 @ <440 Hz
30 Hz to 1 kHz
1.0 + 25
1.0 + 25
1.0 + 25
1.0 + 25
1.0 + 25
1 kHz to 5
2.0 + 25
2.0 + 25
2.0 + 25
2.0 + 25
Burden voltage/Shunt
kHz
-
-
<0.04 V/ 100 Ω
<0.1 V/ 0.01 Ω
<0.3 V/ 0.01 Ω
<0.4 V/ 100 Ω
<0.08 V/ 1 Ω
<1.00 V/ 1 Ω
5 kHz to 20
2.0 + 40
2.0 + 40
2.0 + 40
kHz
-
-
-