Specifications of 503

Dmm Type
Clamp
Voltage Measuring Range Dc
0.2V To 600V
Voltage Measuring Range Ac
0.5V To 600V
Current Measuring Range Dc
0.1A To 400A
Current Measuring Range Ac
0.05A To 400A
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
503
Manufacturer:
SHARP
Quantity:
38 520
Part Number:
5030001300+
Manufacturer:
VOGT
Quantity:
2 949
Part Number:
50300080091
Manufacturer:
PTR
Quantity:
441
Part Number:
5030291020+
Manufacturer:
MOLEX
Quantity:
4 493
Part Number:
5030303520+
Manufacturer:
SHARP
Quantity:
10 000
Specifications
MODELS
AC AMPERES (Auto-Ranging)
Measurement Range
Resolution
Accuracy
Overload Protection
AC VOLTS (Auto-Ranging)
Measurement Range
Resolution
Accuracy
Input Impedance
Overload Protection
DC AMPERES (Auto-Ranging)
Measurement Range
Resolution
Accuracy
Overload Protection
DC VOLTS (Auto-Ranging)
Measurement Range
Resolution
Accuracy
Input Impedance
Overload Protection
RESISTANCE-OHMS (Ω)
Measurement Range
Resolution
Accuracy
Max Test Voltage
Overload Protection
CONTINUITY
Beeper Activation
Max. Test Voltage
Overload Protection
FREQUENCY (Hz) (Auto-Ranging)
CURRENT INPUT
Range
Accuracy
Min Input Signal
Input Impedance
Overload Protection
VOLTAGE INPUT
Range
Accuracy
Min Input Signal 4kHz
Input Impedance
Overload Protection
>40kHz to 400kHz
>4kHz to 10kHz
>4kHz to 40kHz
20Hz to 4kHz
10Hz to 4kHz
60 to 500Hz ±2.8% of Reading ± 5cts
60 to 500Hz ±1.5% of Reading ± 5cts
50 to 60Hz
50 to 60Hz
400kHz
40kHz
400A
400V
600V
400A
400V
600V
40A
40A
Technical Assistance (800) 343-1391
±1.9% of Reading ± 3cts
(Average Sensing)
±2% of Reading ± 5cts
±1% of Reading ± 5cts
0.05 to 400A
0.3 to 400Ω
0.5 to 600V
600Vrms
600Vrms
600Arms
600Vrms
1.5V
1.5V
500
<35Ω
0.01A
0.1Ω
1MΩ
0.1A
0.1V
1V
DC
DC
±1.9% of Reading ± 5cts
±2.5% of Reading ± 5cts
±0.8% of Reading ± 5cts
±1.5% of Reading ± 5cts
(Average Sensing)
±1% of Reading ± 2cts
±0.1% of Reading ± 1ct
±0.1% of Reading ± 1ct
±1% of Reading ± 2cts
100Hz Resolution
10Hz Resolution
10Hz Resolution
1Hz Resolution
1Hz Resolution
0.05 to 400A
0.5 to 600V
0.2 to 600V
0.2 to 400Ω
600Arms
600Vrms
600Vrms
600Vrms
600Vrms
600Arms
600Vrms
501
0.01A
1.5V
1.5V
2Arms
5Vrms
5Vrms
5Vrms
1MΩ
1MΩ
<40Ω
0.1A
0.1V
0.1V
0.1Ω
1MΩ
1MΩ
1V
1V
DC
DC
±1.9% of Reading ± 5cts
±2.5% of Reading ± 5cts
±1.5% of Reading ± 5cts
±1.5% of Reading ± 5cts
±0.1% of Reading ± 1ct
±0.1% of Reading ± 1ct
±1% of Reading ± 2cts
±1% of Reading ± 2cts
100Hz Resolution
Clamp-On Meter Models 500, 501, 502 & 503 (pdf)
0.05 to 400Arms
10Hz Resolution
10Hz Resolution
0.5 to 600Vrms
1Hz Resolution
1Hz Resolution
0.2 to 400Ω
0.2 to 600V
(TRMS)
600Arms
600Vrms
600Vrms
600Vrms
600Vrms
600Arms
600Vrms
502
1.5V
1.5V
2Arms
5Vrms
5Vrms
5Vrms
< 40Ω
0.01A
1MΩ
1MΩ
0.1Ω
1MΩ
1MΩ
0.1A
0.1V
0.1V
1V
1V
DC
DC
±1.5% of Reading ± 10cts
±2.5% of Reading ± 10cts
±2.5% of Reading ± 10cts
±0.8% of Reading ± 5cts
±1.5% of Reading ± 5cts
(Average Sensing)
±1% of Reading ± 2cts
±1% of Reading ± 2cts
www.aemc.com
0.05 to 400A
0.10 to 400A
0.2 to 400Ω
0.5 to 600V
0.2 to 600V
600Arms
600Vrms
600Arms
600Vrms
600Vrms
600Vrms
1.5V
1.5V
503
10MΩ
10MΩ
0.01A
0.01A
<40Ω
0.1Ω
0.1A
0.1V
0.1A
0.1V
1V
1V
DC
DC
Rev. 04
3 of 6
11/04