FLUKE-1577 Fluke, FLUKE-1577 Datasheet - Page 5

MULTIMETER, DIGITAL, HANDHELD

FLUKE-1577

Manufacturer Part Number
FLUKE-1577
Description
MULTIMETER, DIGITAL, HANDHELD
Manufacturer
Fluke
Datasheets

Specifications of FLUKE-1577

Dmm Type
Handheld
Voltage Measuring Range Dc
500-1000V
Voltage Measuring Range Ac
500-1000V
Current Measuring Range Dc
60mA To 400mA
Current Measuring Range Ac
60mA To 400mA
Cable Type
RS-232
Resistance, Range
600 Ohms to 50 Megohms
Standards
CSA per Standard CSA⁄CAN C22.2 No. 61010.1-04, TUV per Standard EN 61010 Part 1-1002
Voltage, Range, Ac
600 mV to 1000 VAC
Voltage, Range, Dc
6 to 1000 VDC
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
1587/1577 General Specifications
Model 1587
Model 1577
Maximum voltage applied to any terminal: 1000 V ac rms
or dc
Storage temperature: -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature: -20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient: 0.05 x (specified accuracy) per °C
for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F)
Relative humidity, non-condensing: < °C
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration: Random, 2 g, 5-500 Hz per MIL-PRF-28800F,
Class 2 instrument
Shock: 1 meter drop per IEC 61010-1 2
drop test, six sides, oak floor)
Electromagnetic compatibility: In an RF field of 3 V/M,
accuracy = specified accuracy except in temperature: specified
accuracy ± 5 °C (9 °F). (EN 61326-1:1997)
Safety: Complies with ANSI/ISA 82.02.01 (61010-1) 2004,
CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2
Edition for measurement CAT III 1000 V and CAT IV 600 V
(0 % to + 20 %)
(0 % to + 20 %)
(0 % to + 20 %)
(0 % to + 20 %)
(0 % to + 20 %)
(0 % to + 20 %)
(0 % to + 20 %)
Output Voltage
Output Voltage
1000 V
1000 V
250 V
500 V
500 V
100 V
50 V
0.01 to 6.00 MΩ
0.01 to 6.00 MΩ
Display Range
Display Range
6.0 to 50.0 MΩ
6.0 to 60.0 MΩ
0.1 to 60.0 MΩ
0.1 to 60.0 MΩ
0.1 to 60.0 MΩ
0.1 to 60.0 MΩ
0.1 to 60.0 MΩ
60 to 100 MΩ
60 to 250 MΩ
60 to 500 MΩ
60 to 600 MΩ
60 to 500 MΩ
60 to 600 MΩ
0.6 to 2.0 GΩ
nd
Edition (1 meter
Resolution
Resolution
0.01 MΩ
0.01 MΩ
100 MΩ
0.1 MΩ
0.1 MΩ
0.1 MΩ
0.1 MΩ
0.1 MΩ
0.1 MΩ
0.1 MΩ
nd
1 MΩ
1 MΩ
1 MΩ
1 MΩ
1 MΩ
1 MΩ
Certifications: CSA per standard CSA/CAN C22.2
No. 61010.1-04; TUV per standard EN 61010 Part 1-1002
Batteries: Four AA batteries (NEDA 15A or IEC LR6)
Battery life: Meter use 1000 hours; Insulation test use: Meter
can perform at least 1000 insulation tests with fresh alkaline
batteries at room temperature. These are standard tests of
1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25
seconds off
Size: 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in
W x 8.00 in L)
Weight: 550 g (1.2 lb)
IP rating: IP40
Altitude (operating): 2000 m CAT III 1000 V, CAT IV 600 V;
3000 m CAT II 1000 V, CAT III 600 V
Storage: 12,000 m
Over-range capability: 110 % of range except for
capacitance which is 1 %
Compliance to EN 61557: IEC61557-1, IEC61557-2
1 mA @ 250 kΩ
1 mA @ 500 kΩ
1 mA @ 500 kΩ
1 mA @ 100 kΩ
1 mA @ 50 kΩ
1 mA @ 1 MΩ
1 mA @ 1 MΩ
Test Current
Test Current
1587/1577 Insulation Multimeters
Resistance Accuracy
Resistance Accuracy
2.0 % + 5 counts
2.0 % + 5 counts
1.5 % + 5 counts
1.5 % + 5 counts
1.5 % + 5 counts
10 % + 3 counts
3 % + 5 counts
3 % + 5 counts
Fluke Corporation 5