Specifications of AVO310-EN

Dmm Type
Handheld
Voltage Measuring Range Dc
400mV, 4V, 40V, 400V, 1000V
Voltage Measuring Range Ac
400mV, 4V, 40V, 400V, 1000V
Current Range Dc
400µA, 4mA, 40mA, 400mA, 10A
Current Range Ac
400µA, 4mA, 40mA,
Resistance Measuring Range
400R, 4kR, 40kR, 400kR, 4MR, 40MR
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Safety
The instrument complies with EN61010-2-32
Powe:
One 9 V battery , NEDA 1604, IEC 6F22
Dimensions
182 (H) x 82 (W) x55 (D) mm
Weight: Approx
375g
Accuracy
Accuracy is given at 18 ºC to 28 ºC (65 ºF to 83 ºF), less than 70 %
RH
DC Voltage (Auto-ranging)
Range
400.0 mV
4.000 V
40.00 V
400.0 V
600 V
Input Impedance: 7.8MΩ.
Maximum Input: 1000 V d.c.
AC Voltage (Auto-ranging)
Range
400.0 mV
4.000 V
40.00 V
400.0 V
1000 V
Input Impedance: 7.8 MΩ.
AC Response: 50Hz 60Hz
Maximum Input: 1000 V rms
DC Current (Auto-ranging)
Range
400.0 µA
4000 µA
40.00 mA
400.0 mA
10 A
Overload Protection: 0.5 A / 1000 V and 10 A / 1000 V Fuse.
Maximum Input:
(AVO310 only)
4000 µA dc on µA range
400 mA dc on mA range
10 A dc on 10 A range.
Resolution
Resolution
Resolution
100 mV
100 mV
0.1 mV
0.1 mV
100 µA
10 mV
10 mV
0.1 µA
10 mA
10 µA
1 mV
1 mV
1 µA
1 V
1 V
+0.5% of rdg ±2 digits
+0.8% of rdg ±2 digits
+1.5% of rdg ±5 digits
+1% of rdg ±5 digits
+2.5% of rdg ± 3 digits
+1% of rdg ±2 digits
+1.0% of rdg ±3 digits
Accuracy
Accuracy
Accuracy
AC Current (Auto-ranging)
Range
400.0 µA
4000 µA
40.00 mA
400.0 mA
10 A
Overload Protection: 0.5 A / 1000 V and 10 A / 1000 V Fuse.
AC Response: 50Hz to 400Hz
Maximum Input:
Resistance [Ω] (Auto-ranging)
Range
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
Input Protection: 1000 V d.c. or 1000 V a.c. rms.
AVO300: Diode Test
Test current
0.3mA typical/Open
<1.5 V
Open circuit voltage: 1.5 V dc typical
Overload protection: 1000 V d.c. or 1000 a.c. V rms
AVO310: Diode Test
Test current
1mA typical/
Open MAX.3 V
Open circuit voltage:
MAX. 3 V dc
Overload protection: 1000 V d.c. or 100 V a.c. rms
Audible continuity
Audible threshold:
AVO300:
Less than10 ohm to 30 ohm Ω
Test current: MAX. 0.3 mA
AVO310:
Less than 35 ohm Ω
Test current MAX. 1.5 mA
Overload protection: 1000 V d.c. or 1000 V a.c. rms
4000 µA ac rms on µA
400 mA ac rms on mA
10 A ac rms on 10 A range.
Resolution
Resolution
Resolution
Resolution
100 µA
10 mA
0.1 µA
100 Ω
10 kΩ
10 µA
0.1 Ω
10 Ω
1 mV
1 mV
1 kΩ
1 µA
1 Ω
+0.8% of rdg ±2 digits
+3% of rdg ±8 digits
+0.8% of rdg ±5 digits
+10% of rdg ±5 digits
+10% of rdg ±5 digits
+3.0% of rdg ±5 digits
+1.5% of rdg ±5 digits
Digital Multimeter
Accuracy
Accuracy
Accuracy
Accuracy
AVO300