F09 CHAUVIN ARNOUX, F09 Datasheet - Page 3

CLAMP METER, CURRENT, TRMS

F09

Manufacturer Part Number
F09
Description
CLAMP METER, CURRENT, TRMS
Manufacturer
CHAUVIN ARNOUX
Datasheet

Specifications of F09

Dmm Type
Clamp
Voltage Measuring Range Dc
0.2V To 600V
Voltage Measuring Range Ac
0.2V To 600V
Current Range Dc
0.2A To 400A
Current Range Ac
200mA To 400A
Resistance Measuring Range
0.2kohm To
Frequency Measuring Range
10Hz To 19.99kHz
Rohs Compliant
NA
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
F09-BA
Manufacturer:
ST
0
Part Number:
F090
Manufacturer:
SURGING
Quantity:
12 800
Part Number:
F090-5AA
Manufacturer:
ST
0
Part Number:
F0903-01
Manufacturer:
FCI
Quantity:
512
Part Number:
F0905D-1W
Manufacturer:
MORNSUN/金升阳
Quantity:
20 000
Part Number:
F090L
Manufacturer:
Bencent
0
Part Number:
F090SMD
Manufacturer:
SURGING
Quantity:
12 799
Part Number:
F090SMD
Manufacturer:
SZVACT
Quantity:
20 000
Part Number:
F095T06
Manufacturer:
SIEMENS
Quantity:
27
Part Number:
F09J-0127GXXXX
Manufacturer:
TDK/东电化
Quantity:
20 000
On the ohmmeter function, the Hold button carries out
lead resistance compensation automatically (
ensuring reliable measurements without necessitating
complex adjustments.
Likewise, in DC ammeter mode, the apparatus also
automatically corrects direct current measurement
variations (DC Zero) by simply pressing on the
function key.
User safety is ensured thanks to the V-live function
integrated on the clamps: a buzzer sounds in voltage
measurement mode, to warn that a potentially dangerous
voltage (greater than 45 V peak) has been detected.
Ease of use and enhanced safety
features
Measuring temperature
Zero),
By the simple
addition of a sensor,
the Temperature
function of
F07
measures both
ambient and surface
temperatures,
in °C or °F.
clamps
After several minutes without use, the clamps switch-
off automatically, optimizing battery autonomy. Light
and robust, the clamps are specially designed for
all-round professional use.
Each clamp automatically selects the nature of the
signal to be measured (AC or DC) and the
measurement range (auto-range). It is however
possible to switch to manual mode as desired.
Enhanced ergonomics
F03
and
Because they are so small
and easy to handle, these
F01
the F07 adapter func-
decades enabling the
of physical quantities
tion : with memorisa-
/
clamps can be used
is made easy, using
F03
tion in scale factor
direct reading of
/
measurements
F05
Measurement
anywhere !
/ F07/
F09