P01105103Z CHAUVIN ARNOUX, P01105103Z Datasheet

no-image

P01105103Z

Manufacturer Part Number
P01105103Z
Description
CLAMP, MINI 03 1A/1MV 100A
Manufacturer
CHAUVIN ARNOUX
Series
MINIr
Datasheet

Specifications of P01105103Z

Dmm Type
Clamp
Current Range Ac
1A To 100A
Dmm Response Type
True RMS
Dmm Functions
AC Current
Current Ac Max
100A
Ranging
Manual
Lead Free Status / RoHS Status
na
Clamp-on ammeter for AC current
MINI series
Small, compact and particularly resistant, this range of
miniature clamps is designed for measurements from a
few milli-amperes to 150 A ac. Their shape makes them
very practical in confined spaces, such as circuit-breaker
boards, control panels or control boxes. They are ideal
for use with multimeters.
There are two types of MINI clamps.
The first type operates like a traditional current transformer
and provides a current output (mA) which can be used
with multimeters, loggers or instruments with current
calibres.
The second provides a voltage output proportional to the
current measured.
Non-contractuel document
906131099 - Ed 1 - 00
1.00
(1/2)
This voltage output enables instruments with AC voltage
calibres to display or store current values.
There is also a model with a DC voltage output.
The MINI clamps give True RMS results when used with
a True RMS instrument.
MINI Series

P01105103Z Summary of contents

Page 1

... There are two types of MINI clamps. The first type operates like a traditional current transformer and provides a current output (mA) which can be used with multimeters, loggers or instruments with current calibres. The second provides a voltage output proportional to the current measured. ...

Page 2

Non-contractuel document 906131099 - 1.00 (2/2) 37.50 ...

Page 3

Clamp-on ammeter for AC current MINI 01 model Calibre 150 A AC Sensitivity (1,000 / 1) Description Small and compact, the MINI 01 clamp-on ammeter is the ideal complement for any multimeter to measure AC currents ...

Page 4

... Ed. 2:2001, EN 61010-2-031 Ed. 2002 & EN 61010-2-032 Ed. 2003 - 600 V category III, pollution degree 2 - 300 V category IV, pollution degree 2 Electromagnetic compatibility: CE-certified equipment compliant with standard EN61326-1 (Ed. 97 (Ed. 98 (Ed. 01) - Emission: stipulations for Class B equipment (domestic use). - Immunity: stipulations for equipment used intermittently on industrial sites. Reference P01105103Z ...

Page 5

Clamp-on ammeter for AC current MINI 05 model Calibres 100 A AC Sensitivities Description Small and compact, the MINI 05 clamp-on ammeter is the ideal complement for any multimeter ...

Page 6

Clamp-on ammeter for AC current MINI 09 model Calibre 150 A AC Sensitivity Description Small and compact, the MINI 09 clamp-on ammeter is the ideal complement for any multimeter to measure AC currents in ...