CM600 GREENLEE TEXTRON, CM600 Datasheet - Page 32

MULTIMETER, DIGITAL, CLAMP, 3-1/2 DIGIT

CM600

Manufacturer Part Number
CM600
Description
MULTIMETER, DIGITAL, CLAMP, 3-1/2 DIGIT
Manufacturer
GREENLEE TEXTRON
Datasheet

Specifications of CM600

Dmm Type
Clamp
Voltage Measuring Range Dc
600V
Voltage Measuring Range Ac
600VAC
Current Measuring Range Ac
600A
Resistance Measuring Range
2000
No. Of Digits / Alpha
3-1/2
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CM6002A
Manufacturer:
MICRO
Quantity:
868
Part Number:
CM6002A
Manufacturer:
CMO
Quantity:
20 000
Part Number:
CM600DU-12H
Manufacturer:
MIT
Quantity:
20 000
Part Number:
CM600DU-24F
Manufacturer:
MITS
Quantity:
1 000
Part Number:
CM600DU-24F
Manufacturer:
MITSUBISHI/三菱
Quantity:
20 000
Part Number:
CM600DU-24F
Quantity:
55
Part Number:
CM600DU-24NF
Manufacturer:
RFMD
Quantity:
1 001
Part Number:
CM600DU-24NF
Manufacturer:
MITSUBISHI/三菱
Quantity:
20 000
Part Number:
CM600DU-24NF#300G
Manufacturer:
PT
Quantity:
64
Part Number:
CM600DU-24NF#300G
Manufacturer:
MITSUBISHI
Quantity:
20 000
Part Number:
CM600DU-24NFH
Quantity:
560
Part Number:
CM600DU-24NFH
Quantity:
55
338
= ReplacemenT paRT
LOCATORS
Locators Application Guide
1. 10,000 ohms and less–both ends isolated from grounds.
2. Does not locate the path–has to be predetermined and only in direct burial applications. 5,000,000 and less.
3. Transmitter connected to metallic shield.
Trace coax cable
Trace concealed wiring in walls and floors
Locate junction box relays and transformers
Locate switch gear
Find shorts to ground
Trace wires in PVC (nonmetallic conduit)
Find opens in a circuit
Localize power and lighting panels
Operate on energized circuits
Operate on low voltage circuits
Operate on high voltage circuits (600VAC)
Operate on unenergized circuits
Trace shielded cable
Trace buried metal conduit
Auto gain circuitry for improved accuracy
AC voltage range
DC voltage range
Distance–receiver from transmitter
Transmitter battery
Receiver battery
= accessoRy
bLL-200
5,000 ft.
0-600V
0-300V
(4) AA
(4) AA
0-240V
0-500V
(8) AA
(1) 9V
4. Will trace coax providing the bOnd is in place at the remote end–will disrupt service.
5. No sorting (high RF bleeds) can trace coax if transmitter connected to braid.
6. Low frequency locators need a “path to earth” (dirt), 5000 ft. on an open conductor and 2500 ft. on a metallic pipe at 3
7. Direct Connection 4,000 ft at 7 ft deep
501
ft. deep.
Inductive Coupler 1,000 ft at 3 ft deep
Inductive Antenna 700 ft at 3 ft deep
3
5
7
rechargeable
PE2003
5000 ft.
0-240V
0-400V
(1) 9V
12V
2
2
1000 ft.
0-240V
0-500V
(1) 9V
(1) 9V
508S
3
5
www.greenlee.com
0-120V
0-250V
(1) 9V
521A
(8) D
1
3
4
6