CM850 GREENLEE TEXTRON, CM850 Datasheet - Page 32

MULTIMETER, DIGITAL, CLAMP

CM850

Manufacturer Part Number
CM850
Description
MULTIMETER, DIGITAL, CLAMP
Manufacturer
GREENLEE TEXTRON
Datasheet

Specifications of CM850

Dmm Type
Clamp
Voltage Measuring Range Dc
400.0, 600V
Voltage Measuring Range Ac
400.0, 600V
Current Measuring Range Ac
600A
Resistance Measuring Range
400.0 Ohm
Frequency Measuring Range
0.400kHz
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CM8500AGIT
Manufacturer:
CHAMPION
Quantity:
1 548
Part Number:
CM8500AIT
Manufacturer:
CHAMPION
Quantity:
280
Part Number:
CM8500AITTR
Manufacturer:
IBM
Quantity:
103
Part Number:
CM8500GIT
Manufacturer:
SMD
Quantity:
635
Part Number:
CM8500I
Manufacturer:
CHAMPION
Quantity:
1 139
Company:
Part Number:
CM8500I
Quantity:
88
Part Number:
CM8501AI
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
CM8501CI
Manufacturer:
CHAMPION
Quantity:
20 000
338
= ReplacemenT paRT
LOCATORS
Locators Application Guide
1. 10,000 ohms and less–both ends isolated from grounds.
2. Does not locate the path–has to be predetermined and only in direct burial applications. 5,000,000 and less.
3. Transmitter connected to metallic shield.
Trace coax cable
Trace concealed wiring in walls and floors
Locate junction box relays and transformers
Locate switch gear
Find shorts to ground
Trace wires in PVC (nonmetallic conduit)
Find opens in a circuit
Localize power and lighting panels
Operate on energized circuits
Operate on low voltage circuits
Operate on high voltage circuits (600VAC)
Operate on unenergized circuits
Trace shielded cable
Trace buried metal conduit
Auto gain circuitry for improved accuracy
AC voltage range
DC voltage range
Distance–receiver from transmitter
Transmitter battery
Receiver battery
= accessoRy
bLL-200
5,000 ft.
0-600V
0-300V
(4) AA
(4) AA
0-240V
0-500V
(8) AA
(1) 9V
4. Will trace coax providing the bOnd is in place at the remote end–will disrupt service.
5. No sorting (high RF bleeds) can trace coax if transmitter connected to braid.
6. Low frequency locators need a “path to earth” (dirt), 5000 ft. on an open conductor and 2500 ft. on a metallic pipe at 3
7. Direct Connection 4,000 ft at 7 ft deep
501
ft. deep.
Inductive Coupler 1,000 ft at 3 ft deep
Inductive Antenna 700 ft at 3 ft deep
3
5
7
rechargeable
PE2003
5000 ft.
0-240V
0-400V
(1) 9V
12V
2
2
1000 ft.
0-240V
0-500V
(1) 9V
(1) 9V
508S
3
5
www.greenlee.com
0-120V
0-250V
(1) 9V
521A
(8) D
1
3
4
6