CMP200 GREENLEE TEXTRON, CMP200 Datasheet - Page 32

MULTIMETER, DIGITAL, CLAMP

CMP200

Manufacturer Part Number
CMP200
Description
MULTIMETER, DIGITAL, CLAMP
Manufacturer
GREENLEE TEXTRON
Datasheet

Specifications of CMP200

Dmm Type
Clamp
Voltage Measuring Range Dc
0 To 600 V
Voltage Measuring Range Ac
499.9, 600 V
Current Measuring Range Dc
2000A
Current Measuring Range Ac
2000A
Frequency Measuring Range
10Hz To 1000Hz
Lead Free Status / RoHS Status
na
338
= ReplacemenT paRT
LOCATORS
Locators Application Guide
1. 10,000 ohms and less–both ends isolated from grounds.
2. Does not locate the path–has to be predetermined and only in direct burial applications. 5,000,000 and less.
3. Transmitter connected to metallic shield.
Trace coax cable
Trace concealed wiring in walls and floors
Locate junction box relays and transformers
Locate switch gear
Find shorts to ground
Trace wires in PVC (nonmetallic conduit)
Find opens in a circuit
Localize power and lighting panels
Operate on energized circuits
Operate on low voltage circuits
Operate on high voltage circuits (600VAC)
Operate on unenergized circuits
Trace shielded cable
Trace buried metal conduit
Auto gain circuitry for improved accuracy
AC voltage range
DC voltage range
Distance–receiver from transmitter
Transmitter battery
Receiver battery
= accessoRy
bLL-200
5,000 ft.
0-600V
0-300V
(4) AA
(4) AA
0-240V
0-500V
(8) AA
(1) 9V
4. Will trace coax providing the bOnd is in place at the remote end–will disrupt service.
5. No sorting (high RF bleeds) can trace coax if transmitter connected to braid.
6. Low frequency locators need a “path to earth” (dirt), 5000 ft. on an open conductor and 2500 ft. on a metallic pipe at 3
7. Direct Connection 4,000 ft at 7 ft deep
501
ft. deep.
Inductive Coupler 1,000 ft at 3 ft deep
Inductive Antenna 700 ft at 3 ft deep
3
5
7
rechargeable
PE2003
5000 ft.
0-240V
0-400V
(1) 9V
12V
2
2
1000 ft.
0-240V
0-500V
(1) 9V
(1) 9V
508S
3
5
www.greenlee.com
0-120V
0-250V
(1) 9V
521A
(8) D
1
3
4
6