U1160A AGILENT TECHNOLOGIES, U1160A Datasheet
U1160A
Specifications of U1160A
U1160A Summary of contents
Page 1
The Agilent U1250 Series handheld digital multimeters (DMMs) exceed your expectations by delivering powerful features and performance that meet your toughest requirements and applications. The series’ latest multimeters, the U1251B, U1252B and U1253B come in vivid orange cases, offering capabilities ...
Page 2
Take a closer look OLED display with approximately 160° viewing angle, and high contrast ratio of 1 2000:1 for crystal-clear viewing SHIFT key and one-stop function keys for easy access Broad range of measurement functions, including temperature and capacitance Built-in ...
Page 3
DC SPECIFICATIONS FUNCTION RANGE 50.000 mV 500.00 mV 1000.0 mV VOLTAGE (1) 5.0000 V 50.000 V 500.00 V 1000.0 V 500.00 W [3] 5.0000 kW [3] 50.000 kW 500.00 kW RESISTANCE (8) 5.0000 MW 50.000 MW [4] [4] 500.00 MW ...
Page 4
U1251B AC VOLTAGE SPECIFICATIONS FUNCTION RANGE 50.000 mV 500.00 mV 1000.0 mV TRUE RMS AC 5.0000 V VOLTAGE [1] [2] 50.000 V 500.00 V 1000.0 V U1251A/U1251B AC CURRENT SPECIFICATIONS FUNCTION RANGE [4] 500.00 µA 5000.0 µA 50.000 mA [2] ...
Page 5
U1252A/U1252B/U1253A/U1253B AC CURRENT SPECIFICATIONS FUNCTION RANGE [4] 500.00 µA 5000.0 µA 50.000 mA TRUE RMS AC [2] [9] CURRENT 440.00 mA 5.0000 A 10.000 A [5] [1] Input impedance: Refer to Table A on page 9. [2] AC mV/V and ...
Page 6
U1252A/U1252B/U1253A/U1253B AC+DC CURRENT SPECIFICATIONS FUNCTION RANGE [6] 500.00 µA 5000.0 µA 50.000 mA TRUE RMS AC CURRENT [10] 440.00 mA 5.0000 A 10.000 A [7] U1251A/U1251B/U1252A/U1252B TEMPERATURE SPECIFICATIONS THERMOCOUPLE RANGE TYPE ºC K –200 ~ 1372 ºC J –210 ~ ...
Page 7
Input impedance: Refer to Table A on page 9. [2] Crest factor ≤ 3.0 at full scale, 5.0 at half scale except the 1000 mV and 1000 V ranges where it is 1.5 at full scale, 3.0 at half ...
Page 8
PEAK HOLD SIGNAL WIDTH Single event > Repetitive > 250 µs [1] DUTY CYCLE AND PULSE WIDTH FUNCTION DUTY CYCLE PULSE WIDTH [1] The positive or negative pulse width must be greater than 10 µs, and the duty ...
Page 9
MEASURING RATE FUNCTION TIMES/SECOND ACV 7 ACV + dB 7 DCV /nS 14 Diode 14 Capacitance 4 (< 100 µF) DCI 7 ACI Temperature 6 Frequency 1 ...
Page 10
GENERAL SPECIFICATIONS DISPLAY Both primary and secondary displays are 5-digit on the LCD display. Both the primary and secondary displays offer a maximum resolution of 50,000 counts. Automatic polarity indication. CONNECTIVITY IR to USB POWER CONSUMPTION 105 mVA / 420 ...
Page 11
... Option 001 Bundled SMT grabbers, fi ne-tip test probes and soft carrying case OPTIONAL ACCESSORIES MEASURING ACCESSORIES (NON-TEMPERATURE) U1160A Standard test lead kit Includes two test leads (red and black), alligator clips, fi ne-tip test probes, SMT grabbers and mini grabber (black). ...
Page 12
... Includes two test leads (red and black), and a pair each of 19-mm and 4-mm test probes. • Test leads: CAT III 1000 V, CAT IV 600 • Test probes (19-mm tip): CAT III 1000 V, CAT IV 600 • Test probes (4-mm tip): CAT III 1000 V, CAT IV 600 ...
Page 13
MEASURING ACCESSORIES (TEMPERATURE) U1186A K-type thermocouple and adapter • T/C adapter J/K-type • T/C bead J-type: –20 °C to 200 °C CABLE U1173A IR-to-USB cable • For remote control and data logging to PC • Max. baud rate: 19,200 bits ...
Page 14
... Spain 34 (91) 631 3300 Sweden 0200- Switzerland 0800 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 1, 2009 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2010 Printed in USA, May 19, 2010 5989-5509EN ...