U8201A AGILENT TECHNOLOGIES, U8201A Datasheet

U3400 U3606A U3401A U3402A

U8201A

Manufacturer Part Number
U8201A
Description
U3400 U3606A U3401A U3402A
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of U8201A

Voltage Rating
1000V
Kit Contents
Extension Test Leads, Test Probes, Alligator Clips, SMT Grabbers, Banana Plugs.
For Use With
U3400 Series, U3401A, U3402A, And U3606A
Lead Free Status / RoHS Status
na
Features
• Two independent instruments
• Nine basic measurements
• Measurement speed: up to
• Low error rate: up to 0.025%
• 30-W dual-range power supply
• Excellent load regulation: up to
• OVP and OCP load protection
• Auto scan and ramp, and
• USB-TMC488.2 and GPIB
• Kensington lock slot security
in one box
as well as 4-wire milliohm
measurement and eight math
functions
37 readings/s
DCV accuracy
with remote sensing
0.01%+3 mV
built-in 4.8 kHz square-wave
generator
connectivity
Agilent U3606A
Multimeter|DC Power Supply
Data Sheet
The real two instruments in one box
Pick both
Digital multimeter (DMM) and power
supply? Simultaneous and inde-
pendent? Small and cost-effective?
Get all this and more in the Agilent
U3606A multimeter|DC power supply.
This convenient new hybrid combines
a 5½-digit DMM and 30-W dual-range
supply in a single unit. Operating
simultaneously and independently,
the instruments provide efficient,
affordable testing while saving space
on the bench or in a rack.
The 5.5-digit DMM
The 5.5-digit DMM includes nine
essential multimeter capabilities as
well as 4-wire milliohm measurement
and eight built-in math functions. The
DMM also provides a fast measure-
ment speed of up to 37 readings/s,
and a low error rate of up to 0.025%
DCV accuracy.
Physical security and seamless
system integration
Instruments may be at risk of theft or
misplacement when left unattended
on the bench. With the hybrid multi-
meter’s rear Kensington lock slot, you
can secure your instrument and be
assured that it is where you expect it
to be for your continued testing the
next day. The rackmountable U3606A
also enables seamless integration
into your system via popular GPIB
and USB-TMC488.2 interfaces,
programmable with standard SCPI
commands.

U8201A Summary of contents

Page 1

Features • Two independent instruments in one box • Nine basic measurements as well as 4-wire milliohm measurement and eight math functions • Measurement speed readings/s • Low error rate 0.025% DCV accuracy • 30-W ...

Page 2

The 30-W DC power supply The 30-W DC power supply provides a dual-range output of 30 V/1 A and 8 V/3 A, with an excellent load regulation 0.01%+3 mV. The power supply adds overvoltage and overcurrent load protection ...

Page 3

Take a closer look Source terminals Multimeter terminals Figure 1. Front panel of the U3606A. AC line fuse AC power connector Figure 2. Rear panel of the U3606A. VFD display Multimeter Autorange operation keys and manual range keys Kensington GPIB ...

Page 4

... Specifications stated are for 2-wire resistance measurements using Null math operation. Without Null, add a 0.2 Ω error. To eliminate noise interfer- ence which may be induced by the test leads, a shielded test cable is recommended for resistances above 100 kΩ. 5. Specifications stated are for the voltage measured at the input terminals only. The test current (1 mA) is typical. Variation in the current source will create some variation in the voltage dropped across a diode junction ...

Page 5

Digital multimeter specifications (continued) Low-resistance specifications Range Test current 100 mΩ 1.0000 A 1000 mΩ 0.1000 A 10 Ω 0.1000 A 1. Four-wire measurement method is used. Test current is sent from the FORCE terminals and resistance is measured at ...

Page 6

Digital multimeter specifications (continued) Frequency specifications Function Input range Frequency Voltage: 100 mV to 750 V 1 Current Minimum frequency sensitivity for voltage measurement (RMS sine wave) 2 Input range 100 kHz ...

Page 7

Digital multimeter specifications (continued) Measurement speeds (typical) Function Rate DC voltage Slow (5½ digits) (10 V) Fast (4½ digits) DC current Slow (5½ digits Fast (4½ digits) AC voltage Slow (5½ digits) ( kHz) Fast ...

Page 8

Digital multimeter specifications (continued) Supplementary specifications AC voltage Measurement method Maximum input voltage Input impedance Input protection Crest factor Peak input Response time Overload ranging AC current Measurement method Maximum input current Burden voltage and shunt resistance Input protection Crest ...

Page 9

Digital multimeter specifications (continued) Supplementary specifications Diode Measurement method Open circuit voltage Audible tone Input protection Capacitance Measurement method Maximum voltage at full scale Input protection Response time Charge and discharge voltage Frequency Measurement method Signal level Input protection Maximum ...

Page 10

Power supply specifications Specification assumptions: • Specifications stated are after 60-minutes of warm-up with no load • Operating temperature: 18 ° °C (64.4 °F to 82.4 °F) • Accuracy is expressed as ±(% of output + offset) at ...

Page 11

Power supply specifications (continued) Sweep specifications Function Range Scan Constant voltage S1 (30 V V/3 A) Constant current S1 (30 V V/3 A) Ramp Constant voltage S1 (30 V V/3 A) ...

Page 12

General characteristics Power supply Power consumption Current Input Fuse Display Operating environment Storage compliance Safety compliance EMC compliance Shock and vibration Remote interface Programming language Measurement category Dimensions (H × W × D) Weight Warranty Calibration cycle Warm-up time • ...

Page 13

... Ordering information Standard shipped items • Quick Start Guide • Product Reference CD • Agilent IO Library Suite • Certificate of Calibration • U8201A Combo Test Lead Kit • USB 2.0 High-Speed Type-A to Type-B cable • AC power cord Optional accessories U8201A Combo Test Lead Kit ...

Page 14

... Spain 34 (91) 631 3300 Sweden 0200- United Kingdom 44 (0) 118 9276201 For other unlisted Countries: www.agilent.com/find/contactus Revised: October 14, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2011 Printed in USA, April 4, 2011 5990-3971EN ...