N2782A AGILENT TECHNOLOGIES, N2782A Datasheet

Current Probe

N2782A

Manufacturer Part Number
N2782A
Description
Current Probe
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of N2782A

Test Probe Type
Oscilloscope
Test Probe Functions
Current
Accuracy
± 1%
For Use With
1000 Series And Infiniium 8000 & 9000 Series Oscilloscopes, Infiniivision 6000 & 7000 Series
Lead Free Status / RoHS Status
na
Figure 1 N2780A Series current probes
with N2779A power supply
• Various bandwidths: DC to 2 MHz,
• DC and AC measurements
• Superior 1% accuracy and high
• Overload-protect function prevents
• Direct connection to high-impedance
• “Demagnetize” button to remove any
• External power supply (N2779A) lets
Compatible with any oscilloscope
with a high-impedance BNC input, the
new N2780A Series current probes
offer accurate and reliable solution for
measuring DC and AC currents.
10 MHz, 50 MHz, 100 MHz
signal-to-noise ratio
probe damage from excessive input
1 MΩ BNC input of oscilloscope
residual magnetism that builds up in
the magnetic core
you connect up to three N278xA
current probes to a single power
supply
N2780A Series AC/DC Current Probes
A wide selection of current probes to meet
your application's needs
Data Sheet
Hybrid technology for AC and DC measurements
Using hybrid technology that includes a Hall-effect sensor and an AC current
transformer, the probes provide accurate measurement of DC or AC currents up to
500 Arms (for model N2780A) or DC–100 MHz (for model N2783A), without break-
ing into the circuit. Using split core construction, the probe easily clips on and off
of a conductor.
Wide range of applications
The current probes feature broad measurement ranges (up to 500 A), flat frequen-
cy response, low noise and low insertion loss that make the probes ideal for cur-
rent measurements in areas such as measuring steady state or transient current
of motor drives, switching power supplies, inverters, controllers, sensors, disk
drives, LCD displays, electronic ballasts and amplifiers. The high signal-to-noise
ratio of the N2782A and N2783A makes them ideal for making low-level current
measurements in milliampere ranges.
Accurate current measurement
A built-in DEMAG (demagnetize) function allows the removal of any residual
magnetism that has built up in the magnetic core due to power on/off switching
or excessive input current. In addition, voltage offset or temperature drift on the
probe can be easily corrected by using the zero adjustment control.
Figure 2 N2783A, N2780A, N2781A and N2782A current probe (from left to right)

N2782A Summary of contents

Page 1

... In addition, voltage offset or temperature drift on the probe can be easily corrected by using the zero adjustment control. Figure 2 N2783A, N2780A, N2781A and N2782A current probe (from left to right) ...

Page 2

... Figure 4 Continuous maximum input rating of N2783A 10M 100M 1M Figure 6. Amplitude accuracy characteristics of N2783A 100 1k 10k 100k Frequency (Hz 0.001 0.01 0.1 1 Input Current ( N2780A, N2781A, N2782A, N2783A and N2774A LEMO inc./FFA..0S.304.CNAC42Z DC (12 V, 2.5 A) 170 VA AC 100-240 VAC, 50/60 Hz, 125-170 VAC 1M 10M 100M 10 100 DC ...

Page 3

... MHz/500A AC/DC current probe N2781A 10 MHz/150A AC/DC current probe N2782A 50 MHz/30A AC/DC current probe N2783A 100 MHz/30A AC/DC current probe N2779A 3-channel power supply for N2780A Series current probes N2782A N2783A MHz DC to 100 MHz less 3 less peak 50 A peak ...

Page 4

... Sweden 0200- Switzerland 0800 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/fi nd/contactus Revised: October 1, 2008 Product specifi cations and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2009 Printed in USA, June 26, 2009 5989-6432EN ...