GLD450 KANE KAY, GLD450 Datasheet - Page 2
GLD450
Manufacturer Part Number
GLD450
Description
PROBE, GAS LEAK DETECTOR
Manufacturer
KANE KAY
Datasheet
1.425_KIT.pdf
(2 pages)
Specifications of GLD450
Svhc
No SVHC (15-Dec-2010)
Lead Free Status / RoHS Status
na
The most user friendly “5 in 1” analyser available
Combustion Analyser
•
•
•
•
•
•
•
•
CO Meter
Calibrate the analyser in fresh air to set the CO
sensor to zero
•
•
•
•
•
•
Gas Leak Detector
•
•
•
Select “Ratio” on the rotary switch to view
current fuel, CO/CO
Select “O
efficiency
Select “Aux” to view any 4 parameters, user
selectable
Measures O
Calculates CO
and combustion efficiency, (nett, gross or
condensing)
Multi fuel - Natural gas, Propane, Butane, LPG
and Light Oils (28/35sec)
Readings can be printed via an infra-red printer,
(see printout example)
Memory stores up to 99 combustion tests
Select “Ratio” to check the ambient CO level in
a room
Select “Room CO” to perform a 15 minute CO
test
The CO level is logged at 1 minute intervals
“Room CO” tests are automatically stored in the
memory
Tests can be printed via an infra-red printer,
(see printout example)
Memory stores up to 20 “Room CO” tests
Plug-in, handheld unit with the sensor at the tip
of a flexible shaft
LED’s and a variable buzzer enable the user to
pinpoint a gas leak
Can detect leaks down to 50ppm of methane /
natural gas
2
/Eff” to view O
2
, CO, inlet and flue temperatures
(#4)
2
, CO/CO
2
ratio, CO, and CO
2
ratio, excess air, losses
2
, temperatures and
(#5), optional
(#1)
2
“Made to Measure” for
6
CORGI
/
Registered Engineers
Differential Pressure Meter
•
•
•
•
•
•
•
•
•
•
•
Differential Thermometer
•
•
•
•
•
Torch Light
•
•
Select “Prs” on the rotary switch for high
accuracy single or differential pressure
readings
Range ± 80mBar, maximum resolution
0.001mBar
Ideal for difficult applications such as flue
draught
Readings can be smoothed to damp out
pressure pulsing
Ideal for setting air/gas ratio valves
Display includes a clock for manual timing,
let-by test
Readings can be printed via an infra-red
printer, (see printout example)
Memory stores up to 20 pressure tests
Select “Tightness” to perform a let-by test and
stabilisation/tightness test
The let-by period defaults to 1 minute
The stabilisation period defaults to 1 minute
The tightness test period defaults to 2 minutes
All 3 times can be adjusted by the user
Tests are automatically stored in the memory
Tests can be printed via an infra-red printer,
(see printout example)
Memory stores up to 20 “Tightness” tests
Select “Diff Temp” to view flow (T1), return
(T2) and differential (∆T) temperatures
Temperature probes are available to measure
air, liquid and surface (pipe) temperatures
Ideal for Benchmark log book
Readings can be printed via an infra-red
printer, (see printout example)
Memory stores up to 20 differential
temperature tests
Never got a torch when you need one? You
have now!
The KANE425 has a backlit display and an
inbuilt LED torch
(#6)
(#3)
(#2)