608-H2 TESTO, 608-H2 Datasheet - Page 11

HYGROMETER

608-H2

Manufacturer Part Number
608-H2
Description
HYGROMETER
Manufacturer
TESTO
Datasheet

Specifications of 608-H2

Humidity Range
2% To 98%
Resolution (°c)
0.1°C
External Height
120mm
External Width
89mm
External Depth
40mm
Svhc
No SVHC (15-Dec-2010)
Accuracy %
2%
Battery Size Code
9V
Operating Temperature Max
70°C
Humidity/temperature probe
Robust humidity probe for meas. up to +125 °C,
short-term up to +140 °C, Ø 12 mm, e.g. exhaust
ducts, and for meas. of material equilibrium
moisture, e.g. bulk goods
Thin humidity probe with built-in electronics, incl.
4 attachable PTFE protection caps for material
moisture equilibrium measurement
Scatter field probe for fast and damage-free
material moisture measurement, with probe
cable 1.2 m.
Pressure dewpoint probe for measurements in
compressed air systems
Precision pressure dewpoint probe for
measurements in compressed air systems,
including certificate with test point -40°C tpd
Absolute pressure probe 2000 hPa
Robust air probe, T/C Type K
Fast-action surface probe with sprung thermocouple strip,
also for uneven surfaces, measurement range short-term
to +500°C, TC Type K
Temperature probe to determine U-value, triple
sensor system for measuring wall temperature,
modelling clay included
Note: Only the measuring instrument testo 635-2 is
suitable for U-value measurement!
Fixed cable
Fixed cable
Fixed cable
Fixed cable
**when used with an NTC or wireless humidity probe for measuring outside temperature and 20 K difference between the air inside and outside
300 mm
300 mm
Ø 4 mm
60 mm
Ø 12 mm
115 mm
Ø 5 mm
300 mm
115 mm
Ø 4 mm
Ø 12 mm
Ø 12 mm
-20 to +70 °C
0 to +100 %RH
0 to +100 %RH
-20 to +125 °C
0 to +100 %RH
0 to +40 °C
Woods:
Building materials:
-30 ... +50 °C tpd
0 to +100 %RH
-60 to +50 °C tpd
0 to +100 %RH
0 to +2000 hPa
-60 to +400 °C
-60 to +300 °C
-20 to +70 °C
In order to determine the U-value, an additional probe for determining the outside
temperatiure is required: 0613 1001 or 0613 1002 (recommended) or 0602 1793.
*According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.
20 %
50 %
±0.3 °C
±2 %RH (+2 to +98 %RH)
±2 %RH (+2 to +98 %RH)
±0.2 °C
±2 %RH (+2 to +98 %RH)
±0.2 °C
±0.9 °C tpd (+0.1 to +50 °C tpd)
±1 °C tpd (-4.9 to 0 °C tpd)
±2 °C tpd (-9.9 to -5 °C tpd)
±3 °C tpd (-19.9 to -10 °C tpd)
±4 °C tpd (-30 to -20 °C tpd)
±0.8 °C tpd (-4.9 to +50 °C tpd)
±1 °C tpd (-9.9 to -5 °C tpd)
±2 °C tpd (-19.9 to -10 °C tpd)
±3 °C tpd (-29.9 to -20 °C tpd)
±4 °C tpd (-40 to -30 °C tpd)
±5 hPa
Class 2*
Class 2*
Class 1; U-value: ±0.1 ±2% of fsv
300 s
300 s
25 s
3 s
0636 9735
0636 2161
0636 2135
0636 6160
0636 9835
0636 9836
0638 1835
0602 1793
0602 0393
0614 1635