... Operates from a 3. Supply ♦ -40°C to +95°C Operating Temperature Range Applications PART DS1856E-050 DS1856E-050/T&R DS1856B-050 Ordering Information continued at end of data sheet. +Denotes lead-free package. T&R denotes tape-and-reel package. Note: All devices are specified over the -40°C to +95°C tem ...
Page 2
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection ABSOLUTE MAXIMUM RATINGS Voltage Range on V Relative to Ground ...........-0.5V to +6.0V CC Voltage Range on Inputs Relative to Ground* ..............................................-0. Voltage Range on Resistor Inputs ...
Page 3
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection ANALOG RESISTOR CHARACTERISTICS (V = 2.85V to 5.5V -40°C to +95°C, unless otherwise noted PARAMETER Position 00h Resistance (50k ) Position FFh Resistance (50k ) ...
Page 4
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection AC ELECTRICAL CHARACTERISTICS (V = 2.85V to 5.5V -40°C to +95°C, unless otherwise noted. See Figure 6 PARAMETER SYMBOL SCL Clock Frequency (Note 9) Bus ...
Page 5
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Note 10: After this period, the first clock pulse is generated. Note 11: The maximum t only has to be met if the device does not stretch the LOW ...
Page 6
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection (V = 5.0V +25°C, for both 50k and 20k versions, unless otherwise noted RESISTOR 0 DNL (LSB) 1.0 0.8 0.6 0.4 0.2 0 -0.2 -0.4 ...
Page 7
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection (V = 5.0V +25°C, for both 50k and 20k versions, unless otherwise noted POSITION 00h RESISTANCE vs. TEMPERATURE 0.38 20k VERSION 0.37 0.36 0.35 0.34 ...
Page 8
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection PIN BALL NAME 1 B2 SDA 2-Wire Serial Data I/O Pin. Transfers serial data to and from the device SCL 2-Wire Serial Clock Input. Clocks data into ...
Page 9
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection AD (AUXILIARY DEVICE ENABLE A0h) DEVICE MD (MAIN DEVICE ENABLE) ADDRESS DEVICE ADDRESS ADEN ADFIX SDA ADDRESS 2-WIRE INTERFACE DATA BUS SCL R/W TxF Tx FAULT OUT1 MINT IN1 ...
Page 10
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Table 1. Scales for Monitor Channels at Factory Setting +FS +FS SIGNAL SIGNAL (hex) Temperature +127.984 7FFC V 6.5528V FFF8 CC MON1 2.4997V FFF8 MON2 2.4997V FFF8 MON3 2.4997V ...
Page 11
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Table 4. ADEN Address Configuration ADEN NO. OF SEPARATE (ADDRESS DEVICE ENABLE) ADDRESSES (Main Device Only) 2-WIRE ADDRRESS A0h DEC HEX DEC HEX 0 0 ...
Page 12
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection 2-WIRE ADDRRESS A2h (DEFAULT) DEC HEX 0 0 00h LOWER MEMORY PASSWORD ENTRY (PWE) (4 BYTES) 127 7F TABLE SELECT BYTE 7Fh 128 80 80h TABLE 00h/01h EEPROM 183 ...
Page 13
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection The DS1856 2-wire interface uses 8-bit addressing, which allows up to 256 bytes to be addressed tradi- tionally on a given 2-wire slave address. However, since the Main Device ...
Page 14
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Word 0 Row Row (hex) Name Byte 0/8 <1> 00 Threshold Temp Alarm Hi 0 <1> 08 Threshold V Alarm <1> 10 Threshold Mon1 Alarm Hi ...
Page 15
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection 6 60 Temp Value Value Mon1 Value Mon2 Value ...
Page 16
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Word 0 Row Row (hex) Name Byte 0/8 <0> <8> <4> 80 Config Mode 0 <8> 88 Config Int Enable 1 <8> 90 Scale Reserved 0 <8> 98 Scale ...
Page 17
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Word 0 Row Row (hex) Name Byte 0/8 <8> 80 LUT <8> 88 LUT <8> 90 LUT <8> 98 LUT <8> A0 LUT <8> A8 LUT <8> B0 LUT ...
Page 18
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Word 0 Row Row (hex) Name Byte 0/8 <8> 80 LUT <8> 88 LUT <8> 90 LUT <8> 98 LUT <8> A0 LUT <8> A8 LUT <8> B0 LUT ...
Page 19
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Name of Row Name of Byte ............. <Read/Write><Volatile><Power-On-Value> Name of Byte ............. <Read/Write><Nonvolitile><Factory-Default-Setting> Threshold 0 Temp High Alarm ..... <R-all/W-pw2><NV><7FFFh> Temperature measurements above this Temp Low Alarm....... <R-all/W-pw2><NV><8000h> Temperature ...
Page 20
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Threshold 3 Mon2 High Alarm ..... <R-all/W-pw2><NV><FFFFh> Voltage measurements of the Mon2 Mon2 Low Alarm ...... <R-all/W-pw2><NV><0000h> Voltage measurements of the Mon2 Mon2 High Warning. <R-all/W-pw2><NV><FFFFh> Voltage measurements of ...
Page 21
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection A2D Value 1 Mon3 Meas................ <R-all><W-NA><0000h> Unsigned voltage measurement. Reserved .................... <R-all><W-NA><0000h> Status ......................... <R-all><W-see bits><conditional> a) Rhiz.................... <R-all><W-NA><1b> High when resistor outputs are high impedance. b) Soft Hiz.............. ...
Page 22
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection .............. Low Warning Status for MON1 Hi........... High Warning Status for MON1 measurement. f) MON1 Lo .......... Low Warning Status for MON1 measurement. ...
Page 23
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Res0 ........................... <R-pw2><W-pw2+TENb><FFh> The base value used for Resistor 0 Res1 ........................... <R-pw2><W-pw2+TENb><FFh> The base value used for Resistor 1 Reserved .................... <R-pw2><W-pw2><00h> SRAM. Config 1 Int Enable.................. <R-pw2/W-pw2><NV><F8h> ...
Page 24
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Scale 0 V Scale ................... <R-pw2/W-pw2><NV><6.5535V> Controls the Scaling or Gain of the CC MON1 Scale .............. <R-pw2/W-pw2><NV><2.500V> Controls the Scaling or Gain of the MON2 Scale .............. <R-pw2/W-pw2><2.500V> ...
Page 25
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Programming the Look-up Table (LUT) The following equation can be used to determine which resistor position setting, 00h to FFh, should be written in the LUT to achieve a ...
Page 26
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection gain_result = gain_result + 2^n; Force the 90% FS input (2.949075V); Meas2 = read the digital result from the part; If Meas2 >= Clamp then gain_result = gain_result – ...
Page 27
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Power-Up and Low-Voltage Operation During power-up, the device is inactive until V exceeds the digital power-on-reset voltage (POD). At this voltage, the digital circuitry, which includes the 2-wire interface, ...
Page 28
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection A page write is initiated the same way as a byte write, but the master does not send a STOP condition after the first byte. Instead, after the slave ...
Page 29
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Stop data transfer: A change in the state of the data line from low to high while the clock line is high defines the STOP condition. Data valid: The ...
Page 30
Dual, Temperature-Controlled Resistors with Inter- nally Calibrated Monitors and Password Protection Within the bus specifications, a standard mode (100kHz clock rate) and a fast mode (400kHz clock rate) are defined. The DS1856 works in both modes. Acknowledge: Each receiving device, ...
Page 31
... CSBGA DS1856E-030+ 16 CSBGA DS1856E-030+T&R 16 TSSOP DS1856B-030+ 16 TSSOP DS1856B-030+T&R 16 TSSOP DS1856E-002 16 TSSOP DS1856E-002/T&R 16 CSBGA DS1856B-002 16 CSBGA DS1856B-002/T&R 16 CSBGA DS1856B-025 For the latest package outline information www.maxim-ic.com/DallasPackInfo. Printed USA is a registered trademark of Maxim Integrated Products, Inc. RES0/RES1 RESISTANCE PIN-PACKAGE (k ) 20/20 16 CSBGA 30/10 16 CSBGA ...