DS1859E-020/T&R Maxim Integrated Products, DS1859E-020/T&R Datasheet - Page 16

no-image

DS1859E-020/T&R

Manufacturer Part Number
DS1859E-020/T&R
Description
Digital Potentiometer ICs
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1859E-020/T&R

Number Of Pots
Dual
Taps Per Pot
256
Resistance
20 KOhms
Wiper Memory
Non Volatile
Digital Interface
Serial (2-Wire)
Operating Supply Voltage
3.3 V, 5 V
Supply Current
2 mA
Maximum Operating Temperature
+ 95 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.85 V
Package / Case
TSSOP-16
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Dual, Temperature-Controlled Resistors with
Internally Calibrated Monitors
Main Device (continued)
16
LOCATION
MEMORY
(hex)
Bit 7
Bit 7
____________________________________________________________________
70
71
4
3
2
1
0
6
5
4
3
2
1
0
6
5
4
EEPROM/
SRAM
SRAM
SRAM
R/W
R/W
R
R
DEFAULT
SETTING
(hex)
0
0
0
0
0
NAME OF LOCATION
Alarm flags
Alarm flags
MON2U
MON3U
MON1hi
MON1lo
MON2hi
MON2lo
MON3hi
MON3lo
TMPhi
TMPlo
V
V
CC
CC
X
X
hi
lo
This bit goes high after a MON2 update has
occurred for the corresponding measurement
in bytes 66h to 67h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.
This bit goes high after a MON3 update has
occurred for the corresponding measurement
in bytes 68h to 69h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.
This alarm flag goes high when the upper limit
of the temperature setting is violated.
This alarm flag goes high when the lower limit
of the temperature setting is violated.
This alarm flag goes high when the upper limit
of the V
This alarm flag goes high when the lower limit
of the V
This alarm flag goes high when the upper limit
of the MON1 setting is violated.
This alarm flag goes high when the lower limit
of the MON1 setting is violated.
This alarm flag goes high when the upper limit
of the MON2 setting is violated.
This alarm flag goes high when the lower limit
of the MON2 setting is violated.
This alarm flag goes high when the upper limit
of the MON3 setting is violated.
This alarm flag goes high when the lower limit
of the MON3 setting is violated.
CC
CC
setting is violated.
setting is violated.
FUNCTION

Related parts for DS1859E-020/T&R