0805YG105ZAT2A AVX Corporation, 0805YG105ZAT2A Datasheet - Page 2

Cap Ceramic 1uF 16VDC Y5V -20% to 80% SMD 0805 Embossed T/R

0805YG105ZAT2A

Manufacturer Part Number
0805YG105ZAT2A
Description
Cap Ceramic 1uF 16VDC Y5V -20% to 80% SMD 0805 Embossed T/R
Manufacturer
AVX Corporation
Type
Flatr
Datasheets

Specifications of 0805YG105ZAT2A

Package/case
0805
Mounting
Surface Mount
Capacitance Value
1 uF
Dielectric
Y5V
Voltage
16 Vdc
Product Length
2.01 mm
Product Height
1.4(Max) mm
Product Depth
1.25 mm
Tolerance
-20 to 80 %
Capacitance
1.0µF
Voltage - Rated
16V
Temperature Coefficient
Y5V (F)
Mounting Type
Surface Mount, MLCC
Operating Temperature
-30°C ~ 85°C
Applications
General Purpose
Package / Case
0805 (2012 Metric)
Size / Dimension
0.079" L x 0.049" W (2.00mm x 1.25mm)
Thickness
1.40mm Max
Dielectric Characteristic
Y5V
Capacitance Tolerance
+80, -20%
Voltage Rating
16VDC
Capacitor Case Style
0805
No. Of Pins
2
Capacitor Mounting
SMD
Rohs Compliant
Yes
Case Code
0805
Case Size
0805
Dissipation Factor
3.5 %
Dissipation Factor, Test Condition
(Max.)
Insulation Resistance
1000 Megohms
Length
0.079 in. ±0.008 in.
Material, Element
Ceramic
Package Type
Paper⁄Embossed
Temperature, Operating, Maximum
125 °C
Temperature, Operating, Minimum
-55 °C
Termination
SMT
Voltage, Rating
16 VDC
Width
0.049 in. ±0.008 in.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Ratings
-
Lead Spacing
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
0805YG105ZAT2A/4K
478-1427-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
0805YG105ZAT2AK
Quantity:
5
Y5V Dielectric
Specifications and Test Methods
Resistance to
Resistance to
Operating Temperature Range
Solder Heat
Load Life
Humidity
Stresses
Thermal
Flexure
Shock
Load
Insulation Resistance
Dielectric Strength
Dissipation Factor
Parameter/Test
Capacitance
Solderability
Capacitance
Capacitance
Capacitance
Capacitance
Capacitance
Appearance
Appearance
Appearance
Appearance
Appearance
Resistance
Resistance
Resistance
Resistance
Resistance
Dissipation
Dissipation
Dissipation
Dissipation
Dissipation
Insulation
Insulation
Insulation
Insulation
Insulation
Dielectric
Dielectric
Dielectric
Dielectric
Variation
Variation
Strength
Variation
Strength
Variation
Strength
Variation
Strength
Factor
Factor
Factor
Factor
Factor
No defects, <25% leaching of either end terminal
≥ 95% of each terminal should be covered
No breakdown or visual defects
≥ Initial Value x 0.1 (See Above)
≥ Initial Value x 0.1 (See Above)
Meets Initial Values (As Above)
Meets Initial Values (As Above)
Meets Initial Values (As Above)
Meets Initial Values (As Above)
≤ Initial Value x 1.5 (See Above)
Meets Initial Values (As Above)
Meets Initial Values (As Above)
≤ Initial Value x 1.5 (See above)
Meets Initial Values (As Above)
Meets Initial Values (As Above)
Meets Initial Values (As Above)
≤ 12.5% for ≤ 10V DC rating
Y5V Specification Limits
10,000MΩ or 500MΩ - μF,
≤ 5.0% for ≥ 50V DC rating
Within specified tolerance
≤ 7.0% for 25V DC rating
≤ 9.0% for 16V DC rating
≥ Initial Value x 0.1
No visual defects
whichever is less
with fresh solder
No visual defects
-30ºC to +85ºC
No visual defects
No defects
≤ ±30%
≤ ±20%
≤ ±20%
≤ ±30%
≤ ±30%
1-5 seconds, w/charge and discharge current
seconds. Store at room temperature for 24 ± 2
Charge device with 300% of rated voltage for
hours before measuring electrical properties.
Dip device in eutectic solder at 260ºC for 60
Step 1: -30ºC ± 2º
Step 2: Room Temp
Step 3: +85ºC ± 2º
Step 4: Room Temp
Repeat for 5 cycles and measure after
24 ±2 hours at room temperature
Dip device in eutectic solder at 230 ± 5ºC
85% ± 5% relative humidity for 1000 hours
Store in a test chamber set at 85ºC ± 2ºC/
Charge device with twice rated voltage in
Remove from test chamber and stabilize
Remove from chamber and stabilize at
120 ± 5 secs @ room temp/humidity
at room temperature for 24 ± 2 hours
Charge device with rated voltage for
For Cap > 10 μF, 0.5Vrms @ 120Hz
(+48, -0) with rated voltage applied.
room temperature and humidity for
test chamber set at 85ºC ± 2ºC
24 ± 2 hours before measuring.
Temperature Cycle Chamber
Measuring Conditions
for 1000 hours (+48, -0)
Voltage: 1.0Vrms ± .2V
Test Time: 30 seconds
limited to 50 mA (max)
Freq.: 1.0 kHz ± 10%
for 5.0 ± 0.5 seconds
before measuring.
Deflection: 2mm
90 mm
1mm/sec
30 ± 3 minutes
≤ 3 minutes
30 ± 3 minutes
≤ 3 minutes
27