10-194632-7I Amphenol, 10-194632-7I Datasheet - Page 23

no-image

10-194632-7I

Manufacturer Part Number
10-194632-7I
Description
Conn MIL-C-22992 Circular PIN 35 POS Solder ST Cable Mount 35 Terminal 1 Port
Manufacturer
Amphenol
Type
MIL-C-22992 Circularr
Datasheet

Specifications of 10-194632-7I

Gender
PL
Termination Method
Solder
Mounting
Cable Mount
Body Orientation
Straight
MIL-C-22992, Class L
installation instructions
Contact Installation
Step 1) Insert stripped conductors in contact wirewells.
If contact bushing is used, insert conductor in bushing
and bushing in contact wirewell. If two or more ground
wires are inserted into a single contact, make sure all
wires are fully seated in wirewell.
Step 2) Select correct crimping tool, locater and die
combination from the table for contacts to be installed.
With conductor or contact bushing in place, insert contact
into tool. Close crimping die fully to form a uniform crimp.
* Available from Pico Crimping Tools Co.,
If crimping tools are available, contacts may be affixed to
conductors by soldering. Use rosin-alcohol solder flux, a
good grade of 60/40 solder and a 500 watt soldering iron
or probe type resistance soldering equipment. Pre-tin
conductors before soldering. Solder must not be present
on shoulder or retention area of contact.
M39029/48-327
M39029/49-335
M39029/48-328
M39029/48-323
M39029/49-333
M39029/48-324
M39029/48-320
M39029/49-331
M39029/48-321
M39029/48-322
M39029/49-332
M39029/48-317
M39029/49-329
M39029/48-318
M39029/48-319
M39029/49-330
9832 Jersey Ave.
Santa Fe Springs, CA 90670
Phone: 805-388-5510
Number
Contact
Part
4/0N
1/0N
Size Type
4/0
4/0
1/0
1/0
4N
4G
4G
6N
6G
6G
4
4
6
6
P
S
P
P
S
P
P
S
P
P
S
P
S
P
P
S
Pico Model
Pico Model
Pico Model
Pico Model
Crimping
400B or
400B or
400B or
400B or
400B-1
400B-1
400B-1
400B-1
Tool*
Locator*
4297-1
4297-3
4297-5
4297-6
414DA-4/0N-1 MS90562-1
414DA-1/0N
414DA-4N
414DA-6N
Die*
MS90562-3
MS90562-5
MS90562-6
Removal
Tool
19
Connector Assembly
Step 1) If inserts are not already positioned in the con-
nector shell, align large tab on insert with large slot in
shell and push insert in until it bottoms in shell.
Step 2) Apply a thin coating of Dow Corning DC-4 lubri-
cant to the periphery of contact holes in spacer or grom-
met assembly. Push contacts into rear of spacer or
grommet assembly until locked into contact retainer
bushing.
Step 3) Align contacts with proper holes in insert. Small
key of insert must be aligned with appropriate keyway in
spacer or grommet assembly. Slide contacts into insert
holes until spacer or grommet assembly butts against
insert. A thin film of Dow Corning DC-4 lubricant applied
to the periphery of insert contact holes will provide maxi-
mum sealing efficiency.
Step 4) Assemble accessories to connector. The back
adapter “O” ring should have a very thin film of Dow
Corning DC-4 lubricant applied. Outer surfaces only of
gland should be lubricated with a thin film of UniTemp
Grease EP. Avoid getting grease on inside surfaces of
gland and on cable jacket.
Step 5) Tighten retaining nut or gland nut on shell or
adapter. A metal-to-metal seating condition is desireable,
but may not be attainable with maximum cable diameters.
Contact Removal
Step 1) Loosen all rear accessories and slide back along
cable.
Step 2) Remove spacer or grommet assembly with con-
tacts from connector insert.
Step 3) Using the appropriate size contact removal tool,
push tool over front of contact until it bottoms in spacer or
grommet assembly hole. This will open contact retaining
bushing and allow contact to be removed from the spacer
or grommet assembly from the rear. When using jacketed
cable, all contacts should be released from contact reten-
tion bushings before removal from spacer or grommet
assembly is accomplished.