LPT44 Astec Power, LPT44 Datasheet

no-image

LPT44

Manufacturer Part Number
LPT44
Description
AC/DC Power Supply Triple-OUT 5V/12V/-5V 5A/2.5A/0.7A 55W 10-Pin
Manufacturer
Astec Power
Type
Switchingr
Datasheet

Specifications of LPT44

Input Voltage
85 to 264 V
Output Voltage
5|12|-5 V
Maximum Current Rating
1(rms) A
Maximum Output Current
5|2.5|0.7 A
Number Of Outputs
3
Maximum Output Power
55 W
Efficiency
70(Typ) %
Input Frequency
47 to 440 Hz
Operating Temperature
0 to 50 °C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPT44
Manufacturer:
ASTEC
Quantity:
1 000
Special Features
• Universal input
• 3” x 5” footprint
• Less than 1U high
• Remote sense on main output
• Terminal Block option (-T)
• Built-in EMI filter
• Low output ripple
• Adjustable main output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Safety
LPT40 Series
40 Watts
Total Power:
Input Voltage:
# of Outputs:
UL
CSA CSA 22.2-234 Level 3
NEMKO EN 60950/EMKO-TUE
CB
CE
UL60950
E132002
LR53982C
P95100411
(74-sec) 203
1118, 1122, 1123, 1124
Mark (LVD)
Certificate and report
40 - 55 Watts
85 - 264 VAC
120 - 300VDC
Triple
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Input current:
Efficiency:
EMI:
Safety ground
leakage current:
Output
Maximum Power:
Cross regulation:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection:
Remote sense:
8 5-264 VAC
120-300 VDC
47-440 Hz
< 18 A peak @ 115 VAC;
< 36A peak @ 230 VAC, cold start @ 25 °C
1A max. (RMS) @ 115 VAC
70% typical at full load (60% for LPT41)
F CC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted;
VDE 0878 PT3 Class B conducted
< 0.5 mA @ 50/60 Hz, 264 VAC input
40W for convection (LPT41, 25W);
55W with 30CFM forced air (LPT41, 41W)
± 2% on output 1; ±5% on outputs 2, 3
-5, +10% minimum
20ms @ 40W load, 115 VAC nominal line
S hort circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
5.7 to 6.7 VDC on the main output
LPT41: 3.6 to 4.6VDC
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 2.16.09_164
LPT40 Series
1 of 3

Related parts for LPT44

LPT44 Summary of contents

Page 1

LPT40 Series 40 Watts Total Power Watts Input Voltage 264 VAC 120 - 300VDC # of Outputs: Triple Special Features • Universal input • 3” x 5” footprint • Less than 1U high • Remote sense on main output • Terminal Block option (-T) • Built-in EMI filter • Low output ripple • Adjustable main output • Overvoltage protection • Overload protection • ...

Page 2

... Number Voltage Load LPT41(-T) +3.3V 0.5A +5V 0A +12V 0A LPT42(-T) +5V 0.4A +12V 0.2A -12V 0A LPT43(-T) +5V 0.5A +12V 0A -12V 0A LPT44(-T) +5V 0.4A +12V 0.2A -5V 0A LPT45(-T) +5V 0.4A +15V 0.2A -15V 0A LPT46(-T) +5V 0.4A +24V 0.1A +12V 0A LPT47(-T) +5V 0.4A +24V ...

Page 3

... Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.5lbs/0.23kg Remote Sense M2 Connector SK201 _ + Voltage Adj. Pot 0.15" (4) DIA (4 places) LPT44 LPT45 LPT46 LPT47 Line Line Line Line Neutral Neutral Neutral Neutral +12V +15V +24V +24V +5V +5V +5V +5V +5V +5V ...

Related keywords