XC3S200-4PQ208I Xilinx Inc, XC3S200-4PQ208I Datasheet - Page 82

no-image

XC3S200-4PQ208I

Manufacturer Part Number
XC3S200-4PQ208I
Description
FPGA Spartan®-3 Family 200K Gates 4320 Cells 630MHz 90nm Technology 1.2V 208-Pin PQFP
Manufacturer
Xilinx Inc
Series
Spartan™-3r
Datasheet

Specifications of XC3S200-4PQ208I

Package
208PQFP
Family Name
Spartan®-3
Device Logic Units
4320
Device System Gates
200000
Maximum Internal Frequency
630 MHz
Typical Operating Supply Voltage
1.2 V
Maximum Number Of User I/os
141
Ram Bits
221184
Number Of Logic Elements/cells
4320
Number Of Labs/clbs
480
Total Ram Bits
221184
Number Of I /o
141
Number Of Gates
200000
Voltage - Supply
1.14 V ~ 1.26 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
208-BFQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC3S200-4PQ208I
Manufacturer:
Xilinx Inc
Quantity:
10 000
Part Number:
XC3S200-4PQ208I
Manufacturer:
XILINX
0
Spartan-3 FPGA Family: DC and Switching Characteristics
Internal Logic Timing
Table 50: CLB Timing
82
Notes:
1.
2.
3.
Clock-to-Output Times
T
Setup Times
T
T
Hold Times
T
T
Clock Timing
T
T
F
Propagation Times
T
Set/Reset Pulse Width
T
AS
AH
CKO
DICK
CKDI
CH
CL
TOG
ILO
RPW_CLB
The numbers in this table are based on the operating conditions set forth in
The timing shown is for SLICEM.
For minimums, use the values reported by the Xilinx timing analyzer.
Symbol
When reading from the FFX (FFY) Flip-Flop,
the time from the active transition at the CLK
input to data appearing at the XQ (YQ) output
Time from the setup of data at the F or G input
to the active transition at the CLK input of the
CLB
Time from the setup of data at the BX or BY
input to the active transition at the CLK input of
the CLB
Time from the active transition at the CLK input
to the point where data is last held at the F or
G input
Time from the active transition at the CLK input
to the point where data is last held at the BX or
BY input
CLB CLK signal High pulse width
CLB CLK signal Low pulse width
Maximum toggle frequency (for export control)
The time it takes for data to travel from the
CLB’s F (G) input to the X (Y) output
The minimum allowable pulse width, High or
Low, to the CLB’s SR input
Description
www.xilinx.com
0.46
1.27
0.25
0.69
0.76
0.69
Min
0
Table
-
-
-
-5
31.
Max
0.63
0.53
725
Speed Grade
-
-
-
-
-
DS099-3 (v2.5) December 4, 2009
0.53
1.57
0.29
0.79
0.79
0.87
Min
0
-
-
-
-4
Product Specification
Max
0.72
0.61
630
-
-
-
-
-
Units
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
R

Related parts for XC3S200-4PQ208I