3.4 DC/AC Converter Receptacle
SOLARLOK Interconnection System
Assembly and Installation Guidelines
1 Place a single wire seal onto the wire and strip wire
2 Crimp the contact using the correct applicator for the wire gauge (# 114-74013)
3 Place O-ring onto the connector housing; push in wire to stop until contact locks into the housing
4 Push seal into the housing
5 Assembly of the cover cap (not available with every version) and mounting in front panel
■
■
■
All specifications subject to change. Consult Tyco Electronics for latest specifications.
(single wire seals are not available with every version).
Required panel mount hole diameter: Diameter 12.5 mm.
The panel thickness must not be under 1.0 mm.
For environmental protection of the unmated connector, use of the covering cap is recommended.
Cover:
Part No. 1394739-1
(continued)
Catalog 889753-3
Revised 6-2008