IT 362 Schaffner EMC Inc, IT 362 Datasheet

no-image

IT 362

Manufacturer Part Number
IT 362
Description
Manufacturer
Schaffner EMC Inc
Datasheet

Specifications of IT 362

Primary Voltage (max)
1000V
Mounting Style
Through Hole
Lead Style
PC Pin
Pin Count
6
Operating Temp Range
-25C to 70C
Primary Side Inductance
3000uH
Primary Et Constant
3500V/us
Dcr Primary Side Max
2.4Ohm
Dcr Secondary Side Max
300mOhm
Rise Time (max)
400ns
Interwinding Capacitance Max
20pF
Turns Ratio
2:1
Product Height (mm)
72mm
Product Depth (mm)
50mm
Product Length (mm)
50mm
Transformer Type
Pulse Transformer
Lead Free Status / RoHS Status
Compliant
Technical specifications
Nominal operating voltage:
Operating frequency:
Ignition currents:
Rise time:
Test voltage:
Max. partial discharge voltage:
Temperature range (operation and storage):
Flammability corresponding to:
IT pulse transformers are designed to offer
you galvanic isolation for transformer coupled
gate drives. The IT series provides negligible
delays and the possibility of voltage scaling.
They are available with single or double
secondary winding for multiple gate drives.
Choosing the IT product line brings you the
rapid availability of a standard gate drive
transformer. A wide selection on turns ratio,
ignition current and voltages are designed to
offer you the desired standard product.
Pulse transformer with single
secondary winding
Up to 3000V
40kHz max.
500kHz max. for data transmission
0.1 to 3A @ 40°C
0.3 to 2.3μs
U
1.5 x U
-25°C to +70°C (25/70/21)
UL 94V-0 listed materials
Features and benefits
p
/50Hz/2s max. according to VDE 110b
Galvanic separation of drive and power
circuit
Voltage resistance up to 8kV
Ignition current up to 3A
Turns ratio up to 3:1
Galvanic separation.
Voltage resistance up to 8kV.
Allows high potential difference voltage
scaling.
Optional grounded shields.
Vacuum potting.
Very low partial discharge effects.
PCB through hole mounting or faston
types.
Custom-specific versions on request.
nom
Pulse transformers
IT series
Approvals
Typical electrical schematic
Typical applications
Gate drive circuit
Power supplies
Power converters
Frequency converters
Switching applications
DC/DC converters
Line coupling transformers in high-speed
data transmission
prim.
sec.

Related parts for IT 362

IT 362 Summary of contents

Page 1

... Test voltage: Max. partial discharge voltage: Temperature range (operation and storage): Flammability corresponding to: IT pulse transformers are designed to offer you galvanic isolation for transformer coupled gate drives. The IT series provides negligible delays and the possibility of voltage scaling. They are available with single or double secondary winding for multiple gate drives ...

Page 2

... IT 370 1 364* 1 246 2:1 0.1 IT 248 2:1 0.25 IT 362* 2 260 3:1 0.1 * Not suitable for PCB-mounting. Explanations: – rise time at given load resistor R and 70% of the output pulse height. – primary inductance measured at 1kHz (secondary coile open). – L str stray inductance measured at the secondary side, short circuit at the primary side. If there are several secondary coils only one at the time is connected (measuring frequency 10kHz). ...

Page 3

... Prim. 6 237 IT 362 IT 364 IT 370 Tol ±0.2 22 32.2 ±0.2 13 23.7 ±0.2 5 10* 10* 5.5 +1/-0 0.45 Ø0.8 0.7 3 ±0.2 7 ±0.2 3.5 ±0.2 2.5 25 ±0.2 Ø4.2 Ø4.2 May 2008 ...

Related keywords