B59970T1100A062 EPCOS Inc, B59970T1100A062 Datasheet

no-image

B59970T1100A062

Manufacturer Part Number
B59970T1100A062
Description
Thermistors - PTC 1970-A 100-A 62 8X2 PTC Thermistor
Manufacturer
EPCOS Inc
Datasheet

Specifications of B59970T1100A062

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PTC thermistors for overcurrent
protection in telecom applications
Telecom Pair Protector (TPP)
for GR1089 Central Office, SMD
Series/Type:
Date:
© EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
B59970T1100A062
November 2009

Related parts for B59970T1100A062

B59970T1100A062 Summary of contents

Page 1

... PTC thermistors for overcurrent protection in telecom applications Telecom Pair Protector (TPP) for GR1089 Central Office, SMD Series/Type: B59970T1100A062 Date: November 2009 © EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. ...

Page 2

Overcurrent protection for telecom Telecom pair protector (TPP) for GR1089 Central Office Applications Overcurrent protection for telecom applications Suitable for line card applications e.g. POTS, access networks, customer premises equipment (CPE) or integrated voice data (IVD) Features Two resistance-matched PTCs ...

Page 3

... Type 0. 230 V AC 230 T1970 < 100 < 1 Internal circuit Dimensional drawings T1970 Dimensions in mm Please read Cautions and warnings and Important notes at the end of this document 150 t Ordering code S @ 2.5 A, 230 < 0.15 B59970T1100A062 Solder pad Page T1970 I Ordering code B59970T1100A062 ...

Page 4

Overcurrent protection for telecom Telecom pair protector (TPP) for GR1089 Central Office Reliability data Test Standard Electrical endurance, IEC 60738-1 cycling Electrical endurance, IEC 60738-1 constant Damp heat IEC 60738-1 Rapid change IEC 60738-1 of temperature Vibration IEC 60738-1 Shock ...

Page 5

Overcurrent protection for telecom Telecom pair protector (TPP) for GR1089 Central Office Cautions and warnings General EPCOS thermistors are designed for specific applications and should not be used for purposes not identified in our specifications, application notes and data books ...

Page 6

Overcurrent protection for telecom Telecom pair protector (TPP) for GR1089 Central Office Mounting Electrode must not be scratched before/during/after the mounting process. Contacts and housing used for assembly with thermistor have to be clean before mounting. Es- pecially grease or ...

Page 7

Overcurrent protection for telecom Telecom pair protector (TPP) for GR1089 Central Office Symbols and terms A Area C Heat capacity th f Frequency I Current I Maximum current max I Rated current R I PTC current PTC I Residual currrent ...

Page 8

Overcurrent protection for telecom Telecom pair protector (TPP) for GR1089 Central Office t Settling time (for level sensors Rated temperature R T Sensing temperature sense T Operating temperature op T PTC temperature PTC t Response time R T ...

Page 9

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical ...

Related keywords