4400-001LF Tusonix, 4400-001LF Datasheet - Page 13

no-image

4400-001LF

Manufacturer Part Number
4400-001LF
Description
Feed Thru Capacitors 500pF 300Volts -55C + 125C
Manufacturer
Tusonix
Datasheet

Specifications of 4400-001LF

Voltage Rating
300 Volts
Operating Temperature Range
- 55 C to + 125 C
Product
Feed Thru General Purpose
Capacitance
500 pF
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The components in this catalog are manufactured with ceramic dielectrics. To minimize possible damage to the components
during installation, the recommendations below should be followed. For information concerning other installation require-
ments and/or component modifications, consult TUSONIX Customer Engineering at (520) 744-0400.
General Recommendations
Handling:
Lead Soldering:
Flux Removal:
Solder Mount Recommendations
Mounting:
Internal
Electrode
Soldering:
Bushing Mount Recommendations
For Mounting Torque, please see standard hardware dimensions table on page 24.
EIA/Tusonix Tolerance Codes
EIA Code
EIA Code
25
The products listed in this catalog are only a few of the thou-
sands of variations that TUSONIX produces. For custom
component design, please contact the factory direct.
Product Installation Recommendations and EIA codes
Z5
Y5
X5
X7
W
D
R
U
E
F
P
S
T
V
CHARACTERISTICS
TEMPERATURE
◆GMV: TUSONIX Code: Guarantied Minimum Value
Temperature Range
Maximum Cap. Change
-55°C to +125°C
+10°C to +85°C
-30°C to +85°C
-55°C to +85°C
+ 22% -33%
+ 22% -56%
+ 22% -82%
+ 22% -90%
± 3.3%
± 4.7%
± 7.5%
± 10%
± 15%
± 22%
Excessive force or direct impact to the component may result in breakage. Lead bending or cutting,
if necessary, should be done with a support for the lead to prevent mechanical stress to the
component. Components with required lead modifications are available from TUSONIX.
Use a temperature controlled soldering iron with SN60 or SN63 RMA Flux core wire. Maximum
soldering temperature to be 500°F(260°C) with a dwell time of 3 seconds maximum. The use of a
heat sink between the component body and the solder joint is highly recommended.
Optimum flux removal can be achieved by vapor degreasing the components immediately after the
soldering operation. Total immersion of the components is not recommended.
Flux. The oven profile should slowly heat the entire assembly to a reflow temperature of 430°F
(221°C), with a rate of change not to exceed 5°F,3°C/Sec. and a dwell time as short as possible.
temperature of 500°F (260°C) and a dwell of 3 seconds maximum.
Use a convection or infrared oven and SN60 or SN63 solder paste, or solder preforms, with RMA
Use a temperature controlled soldering iron with SN62 silver bearing (2%) RMA Flux core solder
wire. The components should be preheated to 300°F (150°C), then soldered with a maximum
PRODUCT INSTALLATION RECOMMENDATIONS
GMV◆
± 0.1 pF
± 0.25 pF
± 0.5 pF
± 0.3 pF
± 1 pF
± 2 pF
± 3%
± 5%
± 10%
± 2%
Capacitnce
10 pF or
Nominal
Less
CAPACITANCE
TOLERANCE
Code
AA
G
A
B
C
D
E
H
K
F
J
L
I
GMV◆
+50% -20%
± 0.10%
± 0.25%
± 0.50%
+70% -30%
± 1%
± 2%
± 3%
+60% -40%
± 5%
± 10%
+100% -40%
Capacitnce
over 10 pF
Nominal
Please note: Maximum Capacitance for each part
number is determined by the required operating
temperature range and maximum capacitance
change.
Capacitnce
± 20%
± 0.4 pF
± 0.2 pF
MAX.
Nominal
10 pF or
Less
TOLERANCE (Cont.)
CAPACITANCE
Code
W
M
N
Q
R
U
P
S
T
V
X
Y
Z
± 20%
± 30%
+100% -0%
± 15%
± 2.5%
+50% -15%
+30% -20%
+80% -0%
± 7%
+50% -30%
+40% -10%
+50% -0%
+80% -20%
Capacitnce
over 10 pF
Nominal

Related parts for 4400-001LF