MPU200-1012G POWER ONE, MPU200-1012G Datasheet - Page 2

Linear & Switching Power Supplies Single Output AC-DC 200W (12V)

MPU200-1012G

Manufacturer Part Number
MPU200-1012G
Description
Linear & Switching Power Supplies Single Output AC-DC 200W (12V)
Manufacturer
POWER ONE
Type
Open Framer
Datasheet

Specifications of MPU200-1012G

Output Current (max)
17A
Input Voltage
85 to 264V
Output Voltage
12V
Number Of Outputs
1
Output Power (max)
200W
Input Frequency
47 to 63Hz
Efficiency
75%
Screening Level
Commercial
Product Length (mm)
203.2mm
Product Height (mm)
38.1mm
Product Depth (mm)
106.7mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Pin Count
15
Product
Switching
Lead Free Status / RoHS Status
Compliant
Lead Free Status / RoHS Status
Compliant
MCD10010 Rev. 1.1, 27-Jan-10
NOTES:1) This product is not rated for convection applications.
DC Input, Single Output Model Selection
MDU200-1012G
MDU200-1024G
(NOTE 4)
MDU200-1048G
Isolation Diode Option - Offered on single-output models. Add “D” at the end of the part number if an isolation diode is needed.
MPU200 Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Operating Frequency
MDU200 Input Specifications
PARAMETER
Input Voltage - DC
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
MODEL
Model numbers highlighted in yellow or shaded are not recommended for new designs.
2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Derating is required on output voltages above 27VDC. Consult factory.
applied from the input side of the power supply blowing towards the output.
VOLTAGE
OUTPUT
12V
24V
48V
22.8V to 29.2V
ADJUSTMENT
11.6V to 16V
45V to 56V
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
After last AC line peak at 200 watts
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
Per EN61000-3-2.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Switching frequency of Power Factor Correction circuit.
CONDITIONS/DESCRIPTION
Continuous input range.
Lowest DC input voltage that regulation is maintained with full rated loads.
At 200 watts, over DC input range.
36 VDC at full rated load.
Non-user serviceable internally located AC input line fuse.
Consult factory.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
RANGE
CURRENT (NOTE 2) CURRENT (NOTE 2)
MAXIMUM OUTPUT
17.0A
8.35A
4.2A
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
PEAK OUTPUT
19.0A
Page 2 of 6
9.4A
4.7A
REGULATION
MPU200/MDU200 Series Data Sheet
0.1%
0.1%
0.1%
LINE
REGULATION
LOAD
1%
1%
1%
%Pk-Pk (NOTE 3)
MIN
0.95
MIN
RIPPLE & NOISE
100
85
47
15
65
36
34
15
1%
1%
1%
NOM
NOM
100
60
70
www.power-one.com
11.97V to 12.03V
23.95V to 24.05V
INITIAL SETTING
47.9V to 48.1V
ACCURACY
MAX
MAX
8.35
264
120
4.0
63
35
90
75
UNITS
UNITS
ARMS
ARMS
W/VA
VDC
VDC
VAC
APK
kHz
kHz
Hz
ms
ms

Related parts for MPU200-1012G