NTS355-(CF) Emerson Network Power, NTS355-(CF) Datasheet

no-image

NTS355-(CF)

Manufacturer Part Number
NTS355-(CF)
Description
Manufacturer
Emerson Network Power
Type
Enclosedr
Datasheet

Specifications of NTS355-(CF)

Input Voltage
85 to 264V
Output Voltage
24V
Number Of Outputs
1
Input Frequency
47 to 440Hz
Efficiency
85%
Screening Level
Commercial
Product Length (mm)
177.8mm
Product Depth (mm)
101.6mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Pin Count
15
Lead Free Status / RoHS Status
Compliant
Special Features
• Active power factor correction
• IEC EN6100-3-2 compliance
• Remote sense
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• Low output ripple
• 5 V standby
• 12 V fan output
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• Built in OR-ing diode / FET
• Optional fan cover (-CF suffix)
• Optional end fan cover (-CEF suffix)
Safety
• TUV
• UL
• CSA
• cULus
• NEMKO
• AUSTEL
• CB
• CE
Total Power:
Input Voltage:
# of Outputs:
NTS350 Series
350 Watts
60950
0950
60950
60950
60950
60950
Certificate and report
Mark (LVD)
200 - 350 Watts
85 - 264 Vac
120 - 300 Vdc
Single
Electrical Specifications
Input
Input ra nge:
Frequency:
Inrush current:
Efficiency:
EMI filter:
Safety ground leakage
current:
Output
Maximum power:
Adjustment range:
Standby output:
Fan output:
Hold-up time:
Overload protection:
Overvoltage protection: 20 - 35% above nominal output
85 - 264 Vac (wide range)
47 - 440 Hz (47- 63 Hz for -CEF versions)
38 A max., cold start @ 25 °C
85% typical at full load
FCC Class B conducted and radiated; CISPR22 Class B conducted and
radiated; EN55022 Class B conducted and radiated; VDE0878PT3 Class B
conducted and radiated.
< 0.5 mA @ 50/60 Hz, 264 Vac input
200 W for convection; 350 W with 30CFM forced air
± 5%
5 V @ 2 A regulated, ± 5%
12 V @ 1 A, -5 %, +7%, 0.5 A for -CF version
20 ms @ 350 W load, 115 Vac nominal line at factory voltage setting
Short circuit protection on all outputs. Case overload protected @
115 - 130% above peak rating
Embedded Power for
Business-Critical Continuity
Rev. 04.28.10_84
NTS350 Series
1 of 4

Related parts for NTS355-(CF)

NTS355-(CF) Summary of contents

Page 1

NTS350 Series 350 Watts Total Power: 200 - 350 Watts Input Voltage 264 Vac 120 - 300 Vdc # of Outputs: Single Special Features • Active power factor correction • IEC EN6100-3-2 compliance • Remote sense • Power ...

Page 2

... Ordering Information Model Output Minimum Number Voltage Load NTS353 NTS355 NTS358 NTS359 Peak current lasting < 30 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. ...

Page 3

Mechanical Drawing SK1 SK1 -CF option (SEE NOTE 5) -CF option 1.27 (32.26) 1.14 (29. 6.4 (2X) 5.85 (148.7) 6.25 (158. 4.7 (119.6) 5.5 (139.7) 7.0 (177. OR-ing out + V out ...

Page 4

... Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services #6-32 (8 places) Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co. Rev. 04.28.10_84 NTS350 Series ...