Specifications of 1NT91-1

Pole Throw Configuration
SP
Actuator Style
Lever
Current Rating (max)
20A
Ac Voltage Rating (max)
277VVAC
Dc Voltage Rating (max)
250VVDC
Contact Material
Silver Cadmium Oxide
Product Height (mm)
58.7mm
Product Depth (mm)
15.7mm
Operating Temperature Min Deg. C
-40C
Product Length (mm)
28.6mm
Operating Temperature Max Deg. C
71C
Mounting Style
Panel
Contact Form
SPDT
Contact Rating
0.5 Amp to 20 Amps
Termination Style
Quick Connect
Terminal Seal
Sealed
Actuator
Lever, Standard
Lead Free Status / RoHS Status
Compliant
Sensing and Control
Interactive
Catalog...
www.honeywell.com/sensing

Related parts for 1NT91-1

1NT91-1 Summary of contents

Page 1

... Sensing and Control Interactive Catalog... www.honeywell.com/sensing ...

Page 2

... Application Note: Honeywell MICRO SWITCH does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5 amp. NT switches use silver cadmium oxide contacts. For other options, contact the MICRO SWITCH Application Center at 1-800-537-6945 ...

Page 3

... F 14NT1-4 4NT91-4 F 14NT1-6 4NT91 14NT1-8 4NT91-8 F Pull-To-Unlock Standard Lever Lever (Add suffix Termination Style to Standard Solder Q-C Lever Listing) 11NT1-1 1NT91-1 ALL TYPES 11NT1-5 1NT91 11NT1-7 1NT91 11NT1-21 1NT91- 11NT1-31 1NT91- 11NT1-51 1NT91-51 E 11NT1-61 1NT91-61 E 12NT1-1 2NT91-1 ALL TYPES 12NT1-5 ...

Page 4

... Terminal screw Quick Connect Terminals mounting torque is 5 in./lbs. max. 110 Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA der a INTI-1 pull-to-unlock toggle switch with the lever locked in the center posi- tion, add the letter E; i.e., INTI-1E ...

Page 5

... Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA This page intentionally left blank. 1-815-235-6847 International 1-800-737-3360 Canada 111 ...

Page 6

... Application Note: Honeywell MICRO SWITCH does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5 amp. NT switches use silver cadmium oxide contacts. For other options, contact the MICRO SWITCH Application Center at 1-800-537-6945 ...

Page 7

... L192 2 31NT91-8 L191 3 32NT91-2 L191 3 32NT91-3 L192 4 32NT91-4 L192 4 32NT91-6 L192 4 32NT91-8 Electrical Catalog UL Rating Rating Listing Code Code Toggle Q-C L191 1 31NT91-1 L192 2 31NT91-5 L192 2 31NT91-7 L191 1 31NT91-21 L191 1 31NT91-31 L192 2 31NT91-51 L192 2 31NT91-61 L191 3 32NT91-1 L192 4 32NT91-5 L192 4 32NT91-7 ...

Page 8

... Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA This page intentionally left blank. 1-815-235-6847 International 1-800-737-3360 Canada ...

Page 9

... Manual Switches Flat Base Sealed Toggles and Rockers MOUNTING DIMENSIONS (For reference only) Toggle Switches Bushing mounting torque is 10–15 in./lbs. Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA NT Series 1-815-235-6847 International 1-800-737-3360 Canada 115 ...