BT139-800,127 NXP Semiconductors, BT139-800,127 Datasheet - Page 2

TRIAC 800V 16A TO220AB

BT139-800,127

Manufacturer Part Number
BT139-800,127
Description
TRIAC 800V 16A TO220AB
Manufacturer
NXP Semiconductors
Datasheet

Specifications of BT139-800,127

Package / Case
TO-220AB-3
Triac Type
Standard
Mounting Type
Through Hole
Configuration
Single
Current - Hold (ih) (max)
45mA
Voltage - Off State
800V
Current - Gate Trigger (igt) (max)
35mA
Current - Non Rep. Surge 50, 60hz (itsm)
155A, 170A
Current - On State (it (rms)) (max)
16A
Voltage - Gate Trigger (vgt) (max)
1.5V
Current - On State (it (rms) (max)
16A
Rated Repetitive Off-state Voltage Vdrm
800 V
Breakover Current Ibo Max
170 A
Off-state Leakage Current @ Vdrm Idrm
0.5 mA
Gate Trigger Voltage (vgt)
1.5 V
Gate Trigger Current (igt)
70 mA
Holding Current (ih Max)
45 mA
Forward Voltage Drop
1.6 V @ 20 A
Mounting Style
SMD/SMT
Repetitive Peak Forward Blocking Voltage
800 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
568-3667-5
933392570127
BT139-800
Philips Semiconductors
3. Ordering information
Table 2:
4. Limiting values
Table 3:
In accordance with the Absolute Maximum Rating System (IEC 60134).
[1]
9397 750 13358
Product data sheet
Type number
BT139-600
BT139-600F
BT139-800
BT139-800F
BT139-800G
Symbol
V
I
I
I
dI
I
V
P
P
T
T
T(RMS)
TSM
2
GM
stg
j
DRM
t
GM
GM
G(AV)
T
/d
Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may switch to the on-state. The
rate of rise of current should not exceed 15 A/ s.
t
Ordering information
Limiting values
Parameter
repetitive peak off-state voltage
RMS on-state current
non-repetitive peak on-state
current
I
repetitive rate of rise of on-state
current after triggering
peak gate current
peak gate voltage
peak gate power
average gate power
storage temperature
junction temperature
2
t for fusing
BT139-600
BT139-800
Package
Name
TO-220AB
Description
plastic single-ended package; heatsink mounted; 1 mounting hole;
3-lead TO-220AB
Rev. 04.00 — 6 July 2004
Conditions
full sine wave; T
Figure 4
full sine wave; T
prior to surge;
Figure 3
t = 10 ms
I
dI
over any 20 ms period
TM
G
t = 20 ms
t = 16.7 ms
T2+ G+
T2+ G
T2 G
T2 G+
/dt = 0.2 A/ s
= 20 A; I
and
G
Figure 5
= 0.2 A;
Figure 2
mb
j
= 25 C
99 C;
and
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
Min
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
40
BT139 series
Max
600
800
16
155
170
120
50
50
50
10
2
5
5
0.5
+150
125
[1]
Version
SOT78
Unit
V
V
A
A
A
A
A/ s
A/ s
A/ s
A/ s
A
V
W
W
C
C
2
s
Triacs
2 of 12

Related parts for BT139-800,127