ACST210-8BTR STMicroelectronics, ACST210-8BTR Datasheet
ACST210-8BTR
Specifications of ACST210-8BTR
Available stocks
Related parts for ACST210-8BTR
ACST210-8BTR Summary of contents
Page 1
... Features ■ Triac with overvoltage crowbar technology ■ High noise immunity: static dV/dt > 500 V/µs ■ ACST210-8FP, in the TO-220FPAB package, provides insulation voltage rated at 1500 V rms Benefits ■ Enables equipment to meet IEC 61000-4-5 ■ High off-state reliability with planar technology ■ ...
Page 2
Characteristics 1 Characteristics Table 2. Absolute maximum ratings (limiting values) Symbol I On-state rms current (full sine wave) T(RMS) Non repetitive surge peak on-state current I TSM (full cycle sine wave, T ² ² Value for ...
Page 3
ACST2 Table 4. Static electrical characteristics Symbol ( 2 500 µ (1) V Threshold voltage TO (1) R Dynamic resistance D I DRM OUT DRM RRM ...
Page 4
Characteristics Figure 4. On-state rms current versus ambient temperature 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 T (°C) amb 0 Figure 6. Relative variation of thermal impedance versus pulse duration DPAK 1.0E+00 Z th(j-c) Z ...
Page 5
ACST2 Figure 10. Relative variation of critical rate of decrease of main current versus junction temperature (° Figure 12. Non repetitive surge peak on-state ...
Page 6
Application information 2 Application information 2.1 Typical application description The ACST2 device has been designed to switch on and off highly inductive or resistive loads such as pump, valve, fan, or bulb lamp. Thanks to its high sensitivity (I ACST2 ...
Page 7
... A C Mains = 10 ma), but provides a high noise immunity level againast GT Figure 17 represents the ACST2 application, and is used to stress the µ Surge generator 2kV surge Rgene Doc ID 13304 Rev 3 Application information . In addition, the CL Figure 18. The ACST2 Model of the load L R ACST210-8x Rg 7/13 ...
Page 8
Application information Figure 18. Typical current and voltage waveforms across the ACST2 during IEC 61000-4-5 standard test 2.3 Electrical noise immunity The ACST2 is a sensitive device (I simple resistor by a logic level circuit, and still provides a high ...
Page 9
ACST2 3 Ordering information scheme Figure 19. Ordering information scheme AC switch Topology T = Triac On-state rms current Sensitivity Voltage 8 = 800 V Package FP = TO-220FPAB B = DPAK ...
Page 10
Package information 4 Package information ● Epoxy meets UL94, V0 ● Recommended torque (TO-220FPAB): 0.4 to 0.6 N·m In order to meet environmental requirements, ST offers these devices in different grades of ® ECOPACK packages, depending on their level of ...
Page 11
ACST2 Table 7. DPAK dimensions 0.60 MIN. Figure 20. Footprint (dimensions in mm) Ref 6.7 3 6.7 Doc ID 13304 Rev 3 Package ...
Page 12
... ACST210-8B ACST210-8B-TR 6 Revision history Table 9. Document revision history Date 01-Mar-2007 13-Apr-2010 01-Jul-2010 12/13 Marking Package TO-220FPAB ACST2108 DPAK DPAK Revision 1 Initial release. Updated ECOPACK statement. Reformatted for consistency with 2 other datasheets in this product class. 3 Updated Figure 19. Doc ID 13304 Rev 3 ACST2 Weight ...
Page 13
... ACST2 Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. ...