ACST610-8G STMicroelectronics, ACST610-8G Datasheet
ACST610-8G
Specifications of ACST610-8G
Available stocks
Related parts for ACST610-8G
ACST610-8G Summary of contents
Page 1
... GT immunity complying with IEC standards such as IEC 61000-4-4 (fast transient burst test). July 2010 Overvoltage protected AC switch OUT TO-220AB ACST610-8T OUT D²PAK ACST610-8G Figure 1. ® (application Table 1. Symbol I T(RMS DRM RRM I GT TM: ACS is a trademark of STMicroelectronics ...
Page 2
Characteristics 1 Characteristics Table 2. Absolute ratings (limiting values) Symbol I On-state rms current (full sine wave) T(RMS) Non repetitive surge peak on-state current T I TSM initial = 25 °C, ( full cycle sine wave ...
Page 3
ACST6 Table 4. Static characteristics Symbol 500 µs OUT 500 µs OUT p (1) V Threshold voltage T0 (1) R Dynamic resistance d I ...
Page 4
Characteristics Figure 4. On-state rms current versus ambient temperature (free air convection, full cycle) I T(RMS) (A) 2 PAK with copper surface = 1 2 1.5 TO-220FPAB TO220AB I 2 PAK 1.0 0 (°C) ...
Page 5
ACST6 Figure 10. On-state characteristics (maximum values (A) 100 125 ° ° Figure 12. Relative variation of static dV/dt immunity versus junction temperature (gate open) dV/dt ...
Page 6
Application information 2 Application information 2.1 Typical application description The ACST6 device has been designed to control medium power load, such as AC motors in home appliances. Thanks to its thermal and turn off commutation performances, the ACST6 switch is ...
Page 7
... Figure 17. Universal drum motor control – typical diagram 2.2 AC line transient voltage ruggedness In comparison with standard Triacs, which are not robust against surge voltage, the ACST6 is self-protected against over-voltage, specified by the new parameter V switch can safely withstand AC line transient voltages either by clamping the low energy spikes, such as inductive spikes at switch off switching to the on state (for less than 10 ms) to dissipate higher energy shocks through the load ...
Page 8
Application information Figure 18. Overvoltage ruggedness test circuit for resistive and inductive loads for IEC 61000-4-5 standards Filtering unit AC Mains Figure 19. Typical current and voltage waveforms across the ACST6 during IEC 61000-4-5 standard test 8/ ...
Page 9
ACST6 3 Ordering information scheme Figure 20. Ordering information scheme AC switch Topology T = Triac On-state rms current Triggering gate current Repetitive peak off-state voltage 8 = 800 V Package FP ...
Page 10
Package information 4 Package information ● Epoxy meets UL94, V0 ● Cooling method: by conduction (C) ● Recommended torque value (TO220AB, TO220FPAB): 0.4 to 0.6 N·m In order to meet environmental requirements, ST offers these devices in different grades of ...
Page 11
ACST6 Table 7. TO-220FPAB dimensions Ref Dia Doc ID 7297 Rev 10 Package information Dimensions Millimeters Min. Max. Min. A 4.4 4.6 0.173 B ...
Page 12
Package information 2 Table 8. D PAK dimensions Figure 21. Footprint (dimensions in mm) 12/15 Ref FLAT ZONE NO LESS THAN 2mm ...
Page 13
ACST6 2 Table 9. I PAK double track dimensions Ref Cropping D B2 direction Doc ID 7297 Rev 10 Package information Dimensions Millimeters Inches Min. Max. Min. ...
Page 14
... Ordering information 5 Ordering information Table 10. Ordering information Order code ACST610-8FP ACST610-8G ACST610-8GTR ACST610-8R ACST610-8T 6 Revision history Table 11. Document revision history Date Jan-2002 09-May-2005 18-Dec-2009 01-Jul-2010 14/15 Marking Package TO-220FPAB 2 D PAK 2 ACST6108 D PAK 2 I PAK TO-220AB Revision 7F Previous issue. 8 Layout update. No content change. ...
Page 15
... ACST6 Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. ...