W2G115-AG71-12 EBM-Papst Industries Inc, W2G115-AG71-12 Datasheet - Page 2

FAN 127 X 38MM 24VDC

W2G115-AG71-12

Manufacturer Part Number
W2G115-AG71-12
Description
FAN 127 X 38MM 24VDC
Manufacturer
EBM-Papst Industries Inc
Series
W2G115r
Type
Tubeaxialr

Specifications of W2G115-AG71-12

Bearing Type
Ball
Fan Type
Tubeaxial
Size / Dimension
Square - 127mm L x 127mm H x 38mm W
Voltage - Rated
24VDC
Power (watts)
12.0W
Features
Locked Rotor Sensor
Rpm
4050 RPM
Noise
52 dB(A)
Air Flow
160.0 CFM (4.53m³/min)
Termination
2 Terminals
Weight
1.2 lbs (544.3g)
Voltage Range
16 ~ 28VDC
Termination Style
52 dB(A)
External Height
127mm
External Width
127mm
External Depth
38mm
Current Type
DC
Supply Voltage
24VDC
Flow Rate
160CFM
Noise Rating
52dBA
Power Connection Type
Terminal
Brand/series
W2G117
Dimensions
127 x 127 x 38 mm
Noise Level
52 dBA
Power Rating
12 W
Size
5 x 1.5 (127 x 38) In. (mm)
Voltage, Rating
24 V
Flow Rate - Imperial
160CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Static Pressure
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
381-1068
W2G115-AG71-13
W2G115AG7112
W2G115AG7113
1.5 Safety and protective functions
1.6 Electromagnetic radiation
Interference from electromagnetic radiation is possible, e.g. in conjunction
with open and closed-loop control devices.
If unacceptable emission intensities occur when the fan is installed,
appropriate shielding measures have to be taken by the user.
1.7 Mechanical movement
Item no.: 50987-5-9970 · Revision status: KM72138 · Print-out on 02/12/2010 · Created by A. Kehm (VM---) · Page 2 of 8
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W2G115-AG71-12
DANGER
Missing safety device and non-functioning safety device
If there is no safety device, you could be seriously injured, for
example by reaching into the running device with your hands.
NOTE
Electrical or electromagnetic interferences after
integrating the device in installations on the customer's
side.
DANGER
Rotating device
Body parts coming into contact with the rotor and impeller can
be injured.
WARNING
Rotating device
Long hair, loose items of clothing and jewellery could become
entangled and pulled into the device. You could be injured.
WARNING
Flying parts
If safety devices are missing, this may cause fan blades to be
ejected at high speeds, causing bodily harm.
supply voltage and secure the latter from being switched on
again.
Wait until the device stops.
Operate the device only with a fixed and isolating safety
protection and a fixed guard grille. The guard must withstand
the kinetic energy of a fan blade detaching at maximum
speed.
The device is a built-in component. You, the owner/
operator, are responsible for providing adequate protection for
the device.
Instantly stop the device once you detect a missing or
ineffective protective feature.
Verify that the entire setup is EMC compliant.
Secure the device against accidental contact.
Before working on the system/machine, wait until all
parts have come to a standstill.
Do not wear any loose clothing or jewellery while working
on rotating parts.
Protect long hair by wearing a cap.
Take appropriate safety measures. The safety devices must
prevent contact with rotating and electrically live parts.
Operating instructions
1.8 Emission
1.9 Hot surface
1.10 Transport
1.11 Storage
Store the device in a dry and weatherproof manner in the original
packing in a clean environment.
Protect the device from environmental impacts and dirt until the final
installation.
We recommend storing the device for a maximum up to one year to
guarantee proper operation and longest possible service life.
Even devices explicitly suited for outdoor use are to be stored as
described prior to being commissioned. Maintain the storage
temperature, see
chapter 3.5 Transport and storage conditions.
1.12 Disposal
When disposing of the device, please comply with all relevant
requirements and regulations applicable in your country.
WARNING
Depending on the installation and operating conditions,
a sound pressure level greater than 70 dB(A) may arise.
Danger of noise-induced hearing loss
CAUTION
High temperature at the electronics enclosure
Danger of burn injuries
NOTE
Transport of device
Take appropriate technical safety measures.
Protect operating personnel with appropriate safety
equipment, e.g. hearing protection.
Also observe the requirements of local agencies.
Ensure that sufficient protection against accidental contact is
provided.
Transport the device in its original packaging only.
Secure the device so that it does not slip, e.g. by using a
clamping strap.

Related parts for W2G115-AG71-12