W2G130-AA31-01 EBM-Papst Industries Inc, W2G130-AA31-01 Datasheet - Page 4

FAN TUBEAXIAL 150X55MM 12VDC

W2G130-AA31-01

Manufacturer Part Number
W2G130-AA31-01
Description
FAN TUBEAXIAL 150X55MM 12VDC
Manufacturer
EBM-Papst Industries Inc
Series
W2G130r
Type
DC Fanr
Datasheets

Specifications of W2G130-AA31-01

Bearing Type
Ball
Power (watts)
14.0W
Size / Dimension
Round - 150mm Dia x 55mm W
Termination
2 Wire Leads
Fan Type
Tubeaxial
Termination Style
51 dB(A)
Air Flow
203.0 CFM (5.75m³/min)
Voltage - Rated
12VDC
Weight
2.2 lbs (997.9g)
Voltage Range
6 ~ 16VDC
Noise
51 dB(A)
External Diameter
150mm
Current Type
DC
Supply Voltage
12VDC
Noise Rating
51dBA
Size
150 Dia. X 55 D Mm
Diameter
150mm
Power Rating
14W
Operating Input Voltage Range
6V to 16V
Bearings
Ball
Noise Level
51dB
Housing Material
Aluminum Die Cast
Product Length (mm)
150mm
Product Height (mm)
55mm
Product Depth (mm)
172mm
Voltage Rating
12V
Fan Rotation
Counter Clockwise
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Rpm
-
Static Pressure
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
W2G130AA3101
Prerequisites
➜ Check whether the data on the type plate agree with the connection data.
➜ Before connecting the device, ensure that the mains supply voltage matches
➜ Only use cables that are configured for current according to the type plate.
Residual current operated device
Connecting cables with terminals (applicable only to devices with terminal
connection)
4/5
the fan voltage.
NOTE
Device malfunctions are possible
➜ Do not route the control lines of the device directly parallel to the
Recommendation: clearance > 10 cm (separate cable routing). (Not
applicable to DC-fed devices)
If the leakage current of the device is greater than 3.5 mA, a perma-
nent earth wire connection is required. The device can be earthed
using two earth wires with a respective outer conductor cross-sec-
tion or one earth wire with at least 10 mm². (Not applicable to DC-
fed devices)
For 3-phase types and types with active PFC, only universal (type B)
RCD protective devices are permitted.
For 1-phase types without PFC, a universal RCD protective device
(type A) can be used.
Like frequency inverters, RCD protective devices cannot provide
personal safety while operating the device.
WARNING
Terminals and connections have voltage even in a unit that is
shut off
Electric shock
➜ Wait five minutes after disconnecting the voltage at all poles
WARNING
Electric voltage on cable gland
Electric shock
➜ Do not use plastic terminal boxes with metal cable glands.
power supply line. Ensure a sufficiently large clearance.
before touching the unit.
3.3 Checking the connections
➜ Ensure that the power is off.
➜ Secure it from being switched on again.
➜ Check the correct fit of the connecting cables.
3.4 Switching on the device
➜ Inspect the device for visible external damage and the proper function of the
➜ Apply nominal voltage to the voltage supply.
➜ Start the device by changing the input signal.
3.5 Switching off the device
– Switch off the device during operation:
– Switching off the device for maintenance work:
protective features before switching it on.
➜ Switch the device off using the control input in order to protect the device.
➜ Do not switch the motor (e.g. in cyclic operation) on and off by means of the
➜ Separate the device from the supply voltage.
power supply.
WARNING
Hot motor housing
Fire hazard
➜ Ensure that no combustible or flammable materials are located in
the vicinity of the fan.

Related parts for W2G130-AA31-01