R1G220-AB73-52 EBM-Papst Industries Inc, R1G220-AB73-52 Datasheet - Page 8

IMPELLER MTRZD 220X63MM 48VDC

R1G220-AB73-52

Manufacturer Part Number
R1G220-AB73-52
Description
IMPELLER MTRZD 220X63MM 48VDC
Manufacturer
EBM-Papst Industries Inc
Series
R1G220ABr
Type
DC Impellerr

Specifications of R1G220-AB73-52

Bearing Type
Ball
Fan Type
Motorized Impellers
Size / Dimension
Round - 220mm Dia x 71mm W
Voltage - Rated
48VDC
Power (watts)
100W
Features
PWM Control; Speed Sensor (Tach)
Rpm
3100 RPM
Noise
73 dB(A)
Air Flow
597.4 CFM (16.92m³/min)
Termination
4 Wire Leads
Weight
3.1 lbs (1.4kg)
Current Rating
2.4A
Voltage Range
36.0 ~ 57.0VDC
Operating Temperature
-13 ~ 140°F (-25 ~ 60°C)
Termination Style
73 dB(A)
External Depth
71mm
External Diameter
220mm
Current Type
DC
Supply Voltage
48VDC
Flow Rate
597CFM
Noise Rating
73dBA
Power Connection Type
Lead Wires
Operating Input Voltage Range
36V to 57V
Bearings
Ball
Housing Material
Polyamide 6.6
Speed (nominal)
3100rpm
Power Rating
100W
Product Height (mm)
71mm
Line Current
2.4A
Voltage Rating
48V
Operating Temp Range
-25C to 60C
Fan Rotation
Clockwise
Product
Fans
Diameter
220mm
Flow Rate - Imperial
597CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Static Pressure
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
R1G220AB7352
4.5 Checking the connections
4.6 Switch on device
Inspect the device for visible external damage and the proper function of
the protective features before switching it on.
4.7 Switching off the device
Switching off the device during operation:
Switching off the device for maintenance work:
Item no.: 50557-5-9970 · Revision status: KM70943 · Print-out on 10/06/2010 · Created by Y. Uhlmann (VM-TDO) · Page 8 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com
R1G220-AB73-52
Make sure that the power is off (all phases).
Secure it from being switched on again.
Check the correct fit of the connection lines.
Apply the nominal voltage to the voltage supply.
Start the device by changing the input signal.
Switch the device off using the control input in order to protect the
device.
Do not switch the motor (e.g. in cyclic operation) on and off via power
supply.
Disconnect the device from the supply voltage.
WARNING
Hot motor housing
Fire hazard
Ensure that no combustible or flammable materials are
located close to the fan.
Operating instructions
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
Do not perform any repairs on your device. Return the device to ebm-
papst for repair or replacement.
Malfunction/error
Motor does not turn
Impeller running
roughly
Overtemperature of
electronics/motor
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
CAUTION
If control voltage is applied or a speed setpoint is stored,
the motor automatically restarts, e.g. after a power failure.
Danger of injury
If the device remains out of use for some time, e.g. when in
storage, we recommend switching the device on for at least 2
hours to allow any condensate to evaporate and to move the
bearings.
Wait for five minutes after disconnecting the voltage at all
poles before touching the unit.
Keep out of the danger zone of the device.
When working on the device, switch off the mains
supply voltage and secure the latter from being switched on
again.
Wait until the device stops.
Possible cause
Mechanical blockage
Mains supply voltage
faulty
Faulty connection
Imbalance in rotating
parts
Insufficient cooling
Ambient temperature
too high
Unacceptable
operating point
Possible remedy
Switch off, de-
energise, and remove
mechanical blockage
Check mains supply
voltage, restore power
supply
apply control signal
Correct connection,
see connection diagram
Clean the device, if
imbalance still evident
after cleaning, replace
device
Improve cooling if
possible.
Reset by switching
off the mains supply
voltage for at least 20
s after motor standstill
Lower ambient
temperature if
possible.
Reset by reducing
control input to 0.
Check operating point

Related parts for R1G220-AB73-52