KSZ8864RMN Micrel Inc, KSZ8864RMN Datasheet - Page 79

no-image

KSZ8864RMN

Manufacturer Part Number
KSZ8864RMN
Description
IC ETHERNET SW 4PORT 64QFN
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8864RMN

Controller Type
Ethernet Switch Controller
Interface
MII, RMII
Voltage - Supply
1.8V, 2.5V, 3.3V
Operating Temperature
0°C ~ 70°C
Mounting Type
*
Package / Case
*
Lead Free Status / RoHS Status
Supplier Unconfirmed
Current - Supply
-
Lead Free Status / RoHS Status
Supplier Unconfirmed, Lead free / RoHS Compliant
Other names
576-3787
KSZ8864RMN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8864RMNI
Manufacturer:
MICREL
Quantity:
7 143
Part Number:
KSZ8864RMNUB
Manufacturer:
MICREL
Quantity:
101
January 2011
Address
Register 182 (0xB6):
Register 198 (0xC6): Port 1 Rate Limit Control
Register 214 (0xD6): Port 2 Rate Limit Control
Register 230 (0xE6): Port 3 Rate Limit Control
Register 246 (0xF6): Port 4 Rate Limit Control
7 - 5
4
3 - 2
1
0
Register 183 (0xB7):
Register 199 (0xC7): Port 1 Priority 0 Ingress Limit Control 1
Register 215 (0xD7): Port 2 Priority 0 Ingress Limit Control 1
Register 231 (0xE7): Port 3 Priority 0 Ingress Limit Control 1
Register 247 (0xF7): Port 4 Priority 0 Ingress Limit Control 1
7
6 - 0
Name
Reserved
Ingress Rate Limit Flow
Control Enable
Limit Mode
Count IFG
Count Pre
Reserved
Port Based Priority 0 Ingress
Limit
Reserved
Reserved
Description
1 = Flow Control is asserted if the port’s receive
rate is exceeded
0 = Flow Control is not asserted if the port’s receive
rate is exceeded
Ingress Limit Mode
These bits determine what kinds of frames are
limited and counted against ingress rate limiting.
= 00, limit and count all frames
= 01, limit and count Broadcast, Multicast, and
flooded unicast frames
= 10, limit and count Broadcast and Multicast
frames only
= 11, limit and count Broadcast frames only
Count IFG bytes
= 1, each frame’s minimum inter frame gap
(IFG) bytes (12 per frame) are included in Ingress
and Egress rate limiting calculations.
= 0, IFG bytes are not counted.
Count Preamble bytes
= 1, each frame’s preamble bytes (8 per
frame) are included in Ingress and Egress rate
limiting calculations.
= 0, preamble bytes are not counted.
Ingress data rate limit for priority 0 frames
Ingress traffic from this port is shaped according to
the Data Rate Selected Table. See the table follow
the end of Egress limit control registers
79
Mode
R/W
R/W
R/W
R/W
R/W
RO
RO
M9999-012011-1.2
0000000
Default
000
00
0
0
0
0

Related parts for KSZ8864RMN