PLRXPL-VC-S43-22-N JDS UNIPHASE, PLRXPL-VC-S43-22-N Datasheet

no-image

PLRXPL-VC-S43-22-N

Manufacturer Part Number
PLRXPL-VC-S43-22-N
Description
Manufacturer
JDS UNIPHASE
Datasheet

Specifications of PLRXPL-VC-S43-22-N

Number Of Receivers
1
Protocols Supported
IEEE 802.3
Operating Supply Voltage (typ)
3.3V
Operating Temperature Classification
Commercial
Operating Supply Voltage (max)
3.47V
Operating Supply Voltage (min)
3.14V
Pin Count
20
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Supply Current
110mA
Lead Free Status / RoHS Status
Compliant
10 G SFP+ 850 nm Limiting Transceiver,
10 Gigabit Ethernet Compatible
PLRXPL-VC-S43-21-N and PLRXPL-VC-S43-22-N Series
Applications
• Intra data center connectivity
• Enterprise access interconnect
• High-speed storage interconnect
• Disaster recovery/backup connectivity
• High-speed cluster/grid computing
Compliance
• SFF 8431 Revision 2.2
• SFF 8432 Revision 5.0
• SFF 8472 Revision 10.3
• CDRH and IEC60825-1 Class 1 Laser
• FCC Class B
• ESD Class 2 per MIL-STD 883
• UL 94, V0
• Reliability tested per Telcordia GR-468
aggregation
Eye Safety
- Switch and hub
- Mass storage systems
- Host bus adapters
NORTH AMERICA: 800 498-JDSU (5378)
Key Features
The lead-free and RoHS-compliant small form factor pluggable (SFP+) transceiver
from JDSU improves the performance for 10 Gigabit Ethernet (10 G) applications,
and is ideal for high-speed campus and large data center applications. This
transceiver features a highly reliable, 850 nm, oxide, vertical-cavity surface-
emitting laser (VCSEL) coupled to an LC optical connector. The transceiver is
fully compatible with 10GBASE-SR and 10GBASE-SW specifi cations at shorter
link distances, with internal AC coupling on both transmit and receive data signals.
The all-metal housing design provides low EMI emissions in demanding 10 G
applications and conforms to IPF specifi cations. An enhanced digital diagnostic
feature set allows for real-time monitoring of transceiver performance and
system stability, and the serial ID allows for customer and vendor system specifi c
information to be stored in the transceiver. Transmit disable, loss-of-signal, and
transmitter fault functions are also provided. The small size of the transceiver
allows for high-density board designs that, in turn, enable greater aggregate
bandwidth.
COMMUNICATIONS MODULES & SUBSYSTEMS
WORLDWIDE: +800 5378-JDSU
• Compatible with 10 G links
• Uses a highly reliable, 850 nm oxide VCSEL
• Lead-free and RoHS 6/6-compliant
• 0 – 70°C case operating temperature
• Single 3.3 V power supply
• Low power consumption (typically 450 mW)
• Bit error rate < 1 x 10
• Hot pluggable
-12
WEBSITE: www.jdsu.com

Related parts for PLRXPL-VC-S43-22-N

PLRXPL-VC-S43-22-N Summary of contents

Page 1

... G SFP+ 850 nm Limiting Transceiver, 10 Gigabit Ethernet Compatible PLRXPL-VC-S43-21-N and PLRXPL-VC-S43-22-N Series Applications • Intra data center connectivity - Switch and hub - Mass storage systems - Host bus adapters • Enterprise access interconnect • High-speed storage interconnect • Disaster recovery/backup connectivity • High-speed cluster/grid computing ...

Page 2

... G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPATIBLE Section 1 Functional Description The PLRXPL-VC-S43-xx-N 10G SFP+ 850 nm optical transceiver is designed to transmit and receive 10 G serial optical data over 50/125 µm or 62.5/125 µm mul- timode optical fi ber. Transmitter The transmitter converts serial PECL or CML electrical data into serial optical data compatible with the 10GBASE-SR and 10GBASE-SW standard. Transmit data lines (TD+ and TD-) are internally AC coupled, with 100 Ω ...

Page 3

VCC_TX TX_DIS TOSA TX_GND SCL Management Processor SDA EEPROM VCC_RX ROSA RX_GND Figure SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPATIBLE 10 kΩ TD+ Laser Driver 100 Ω TX_FAULT Ω 50 VCC_RX RD ...

Page 4

Vcc 10 kΩ Receiver (Tx Fault) CMOS, TTL, or Open Collector Driver Vcc (Tx Disable) Rp*** Open Collector Bidirectional SDA Vcc *** Rq Open Collector Bidirectional Vcc SCL Vcc 10 kΩ R5 ∗∗ Mod_ABS CMOS or TTL Driver (RS0 ...

Page 5

Power Supply Filter Component Values Component L1, L2 Rx, Ry C1, C5 C2, C3 Notes: Option A is recommended for use in applications with space constraints with power supply noise less than 33 mV Option B is ...

Page 6

... Module Outline • Section 3.11 Transceiver Belly-to-belly Mounting 3.1 Pin Function Defi nitions RS1 EE 12 RD- R _LOS X 13 RD+ RS0 _ABS SCL SDA TX_D ISABLE 18 TD+ TX_F AULT 19 TD Figure 3 Host PCB SFP+ Pad assignment top view OWARD 4 B EZEL PLRXPL-Vx-SH4-21xN JDSU | ...

Page 7

SFP+ Optical Transceiver Pin Descriptions Pin Number Symbol Name Receiver 8 LOS Loss of Signal Out (OC) 10, 11 Receiver Signal Ground eeR 12 RD- Receiver Negative DATA Out (PECL) 13 RD+ Receiver Positive DATA Out (PECL) ...

Page 8

... Absolute maximum ratings represent the damage threshold of the device. Damage may occur if the device is subjected to conditions beyond the limits stated here. 3.3 Operating Conditions Part Number PLRXPL-VC-S43-xx-N Note: Performance is not guaranteed and reliability is not implied for operation at any condition outside these limits SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPATIBLE ...

Page 9

Electrical Characteristics Parameter Symbol Supply voltage V cc Power consumption P diss Data rate Transmitter Supply current I ccT Data input voltage swing V TDp-p Data input rise/fall time ∆t Data input skew Data dependent input jitter DDJ ...

Page 10

Optical Characteristics Parameter Symbol Transmitter λ Wavelength p RMS spectral width Transmitter dispersion penalty TDP Average optical power P AVG Optical modulation amplitude OMA Relative intensity noise RIN Receiver λ Wavelength Maximum input power P max Sensitivity (OMA) ...

Page 11

Link Length Data Rate / Standard Fiber Type 10.3 GBd 62.5/125 µm MMF 50/125 µm MMF 50/125 µm MMF 50/125 µm MMF 50/125 µm MMF 10 G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPATIBLE Modal Bandwidth ...

Page 12

... The PLRXPL-VC-S43-xx-N optical transceiver is lead-free and RoHS-compliant per Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in elec- trical and electronic equipment ...

Page 13

PCB Layout 10 G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPATIBLE Figure 4 Board layout Figure 5 Detail layout ALL DIMENSIONS ARE IN MILLIMETERS ...

Page 14

Front Panel Opening 3.10 Module Outline 10 G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPATIBLE Figure 6 ALL DIMENSIONS ARE IN MILLIMETERS Figure 7 ...

Page 15

Transceiver Belly-to-belly Mounting 10 G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPATIBLE Figure 8 ...

Page 16

... Eye safety 4.1 Digital Diagnostic Monitoring and Serial ID Operation The PLRXPL-VC-S43-xx-N optical transceiver is equipped with a two-wire serial EEPROM that is used to store specifi c information about the type and identi- fi cation of the transceiver as well as real-time digitized information relating to the transceiver’s performance. See the Small Form Factor Committee document number SFF-8472 Revision 10.3, dated December 1, 2007 for memory/address organization of the identifi ...

Page 17

Data Field Descriptions Address( 1010000X)(A0h) 0 Serial ID Information; Defined by SFP MSA 95 JDSU-Specific Information 127 Reserved for SFP MSA 255 10 G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPATIBLE Reading the data The information is ...

Page 18

... OM3 50/125 µm multimode fiber JDSU Vendor Name (ASCII) 00 Reserved 00019C IEEE Company ID (ASCII) PLRXPLVCS43xxN Part Number (ASCII part number variable Revision of part number (ASCII) 0352 Wavelength of laser in nm; 850 Unallocated CC_BASE Check Code; Lower 8 bits of sum from byte 0 through 62 ...

Page 19

Diagnostics Data Map Memory Address Value 00-01 Temp High Alarm 02-03 Temp Low Alarm 04-05 Temp High Warning 06-07 Temp Low Warning 08-09 Voltage High Alarm 10-11 Voltage Low Alarm 12-13 Voltage High Warning 14-15 Voltage Low Warning 16-17 ...

Page 20

Diagnostics Data Map Memory Address Value 101 TX Bias LSB (Note 1) 102 TX Power MSB (Note 1) 103 TX Power LSB (Note 1) 104 RX Power MSB 105 RX Power LSB 106 Reserved MSB 107 Reserved LSB 108 ...

Page 21

... Package and Handling Instructions This product is not compatible with any aqueous wash process. Process plug The PLRXPL-VC-S43-xx-N optical transceiver is supplied with a process plug. This plug protects the transceiver optics during standard manufacturing processes by preventing contamination from air borne particles. Note recommended that the dust cover remain in the transceiver whenever an optical fi ...

Page 22

... Product Description PLRXPL-VC-S43-21 SFP+ SR compatible, limiting electrical interface, 0 – 70˚C, ± 5% Vcc, no rate select, generic, first generation PLRXPL-VC-S43-22 SFP+ SR compatible, limiting electrical interface, 0 – 70˚C, ± 5% Vcc, no rate select, generic, second generation NORTH AMERICA: 800 498-JDSU (5378) Product specifications and descriptions in this document subject to change without notice. © 2008 JDS Uniphase Corporation 30149445 501 1008 PLRXPL-VC-S43-XX-N.DS.CMS.AE ...

Related keywords