BK1608HM102-T Taiyo Yuden, BK1608HM102-T Datasheet - Page 20
BK1608HM102-T
Manufacturer Part Number
BK1608HM102-T
Description
FERRITE BEAD 1000 OHM 0603
Manufacturer
Taiyo Yuden
Series
BKr
Datasheets
1.BK1005LM182-T.pdf
(27 pages)
2.BKP1608HS181-T.pdf
(53 pages)
3.BK1608HM102-T.pdf
(1 pages)
Specifications of BK1608HM102-T
Impedance @ Frequency
1K Ohm @ 100MHz
Current Rating
200mA
Dc Resistance (dcr)
700.0 mOhm Max
Filter Type
Differential Mode - Single
Number Of Lines
1
Package / Case
0603 (1608 Metric)
Mounting Type
Surface Mount
Impedance
1kohm
Ferrite Grade
HM
Dc Resistance Max
0.7ohm
Dc Current Rating
200mA
Ferrite Mounting
SMD
Ferrite Case Style
0603 / 1608
Frequency Max
300MHz
Rohs Compliant
Yes
Features
HM
Frequency
100MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
587-1862-2
BK1608HM102-T
BK1608HM102-T
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
BK1608HM102-T
Manufacturer:
Taiyo Yuden
Quantity:
172 928
Multilayer chip inductors and beads
14. Damp Heat
15. Loading under
16. Loading at High
Note on standard condition: "standard condition" referred to herein is defined as follows:
5 to 35℃ of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20 ± 2℃ of temperature, 60 to 70% relative hu-
midity, and 86 to 106kPa of air pressure. Unless otherwise specified, all the tests are conducted under the "standard condition."
△
(Steady state)
!
RELIABILITY DATA
Temperature
Damp Heat
当社カタログをご使用の際には 「当社製品に関するお断り」 を必ずお読みください。
Item
Appearance :No significant abnormality.
Impedance change:Within ±30%
Appearance :No significant abnormality.
Impedance change:Within ±30%
Appearance :No significant abnormality.
Impedance change:Within ±30%
BK0603 BK1005 BK1608 BK2125
BK2010 BK3216
ARRAY
BKP0603 BKP1005 BKP1608 BKP2125 CK1608 CK2125 CKP2520 LK1005
Specified Value
No
mechanical
damage.
Inductance
change:
Within ±20%
Q change:
Within ±30%
No
mechanical
damage.
Inductance
change:
Within ±20%
Q change:
Within ±30%
No
mechanical
damage.
Inductance
change:
Within ±20%
Q change:
Within ±30%
No
mechanical
damage.
Inductance
change :
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±30%
No mechani-
cal damage.
Inductance
change:
Within
±10%
Q change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±10%
Q
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±10%
Q
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
0.047 to
12.0μH:
Within
±10%
15.0 to
33.0μH:
Within
±15%
Q
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
0.047 to
12.0μH:
Within
±10%
15.0 to
33.0μH:
Within
±15%
Q
change:
Within
±30%
LK1608
No
mechanical
damage.
Inductance
change:
Within
±20%
Q change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±20%
Q
change:
Within
No
mechanical
damage.
Induc-
tance
change:
Within
±20%
Q
change:
Within
±30%
±30%
LK2125
No mechanical damage.
Inductance change:Within ±10%
Q change:Within ±20%
No mechanical damage.
Inductance change:Within ±10%
Q change:Within ±20%
No mechanical damage.
Inductance change:Within ±10%
Q change:Within ±20%
HK0603
△
HK1005
!
Please read the "Notice for TAIYO YUDEN products" before using this catalog.
HK1608
HK2125 HKQ0603S AQ105
(Note 1)
measurement shall be made after 48 ± 2 hrs of
recovery under the standard condition.
BBK Series:
Temperature:40±2℃
Humidity:90 to 95%RH
Duration:500
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
LK、 CK、 CKP、 HK、 HKQ、 AQ Series:
Temperature:40±2℃ (LK、 CK 、 CKPSeries)
Humidity:90 to 95%RH
Duration:500±12 hrs
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
BK Series:
Temperature:40±2℃
Humidity:90 to 95%RH
Duration:500
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
LK、 CK、 CKP、 HK、 HKQ、 AQ Series:
Temperature:40±2℃ (LK、 CK 、 CKPSeries)
Humidity:90 to 95%RH
Duration:500±12 hrs
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
BK Series:
Temperature:125±3℃
Applied current:Rated current
Duration:500
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
LK、 CK、 CKP、 HK、 HKQ、 AQ Series、 BK Series
P type:
Temperature:85±2℃ (LK、 CK 、 CKPSeries)
temperature range -55 to +85℃)
Applied current:Rated current
Duration:500±12 hrs
Recovery:2 to 3 hrs of recovery under the
standard condition after the test. ( See Note 1)
:85±3℃ (BK Series P type)
:85±2℃ (HK1608, 2125)
:85±2℃ (HK1005, AQ105 operating
:125±2℃ (HK0603, HK1005, HKQ0603S,
AQ105 operating temperature range -55 to +125℃)
Test Methods and Remarks
:60±2℃ (HK、 HKQ、 AQ Series)
:60±2℃ (HK、 HKQ、 AQ Series)
+24
−0
+24
−0
+24
−0
hrs
hrs
hrs
4/4
253
5