SX1233IMLTRT Semtech, SX1233IMLTRT Datasheet - Page 40

RF Transceiver Extended Bands Japan-Korea

SX1233IMLTRT

Manufacturer Part Number
SX1233IMLTRT
Description
RF Transceiver Extended Bands Japan-Korea
Manufacturer
Semtech
Datasheet

Specifications of SX1233IMLTRT

Transmitting Current
95mA
Data Rate
600Kbps
Rf Ic Case Style
QFN
No. Of Pins
24
Supply Voltage Range
1.8V To 3.6V
Operating Temperature Range
-40°C To +85°C
Receiving Current
17mA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SX1233IMLTRT
Manufacturer:
INFINEON
Quantity:
4 300
4.3. Listen Mode
The circuit can be set to Listen mode, by setting ListenOn in RegOpMode to 1 while in Standby mode. In this mode,
SX1233 spends most of the time in Idle mode, during which only the RC oscillator runs. Periodically the receiver is woken
up and listens for an RF signal. If a wanted signal is detected, the receiver is kept on and the data is demodulated.
Otherwise, if a wanted signal hasn't been detected after a pre-defined period of time, the receiver is disabled until the next
time period.
This periodical Rx wake-up requirement is very common in low power applications. On SX1233 it is handled locally by the
Listen mode block without using uC resources or energy.
The simplified timing diagram of this procedure is illustrated in Figure 21.
4.3.1. Timings
The duration of the Idle phase is given by t
by t
programmed in the configuration registers via the serial interface.
Both time periods t
configuration register and are calculated as follows:
where ListenResolX is the Rx or Idle resolution and is independently programmable on three values (64us, 4.1ms or
262ms), whereas ListenCoefX is an integer between 1 and 255. All parameters are located in RegListen registers.
The timing ranges are tabulated in Table 16 below.
Table 16 Range of Durations in Listen Mode
Rev 5 - June 2011
ADVANCED COMMUNICATIONS & SENSING
ListenRx
. t
ListenRx
ListenRx
includes the wake-up time of the receiver, described in section 4.2.3. This duration can be
Figure 21. Listen Mode Sequence (no wanted signal is received)
and t
t
ListenRx
ListenResolX
Rx
ListenIdle
01
10
11
t
ListenX
(denoted t
ListenIdle
t
ListenIdle
( ListenCoef = 1 )
=
Min duration
ListenCoef
. The time during which the receiver is on and waits for a signal is given
4.1 ms
0.26 s
64 us
ListenX
Page 40
Idle
in the following text) are fixed by two parameters from the
X
Listen
( ListenCoef = 255 )
Re
Max duration
solX
16 ms
1.04 s
67 s
t
ListenRx
Rx
DATASHEET
www.semtech.com
SX1233
time

Related parts for SX1233IMLTRT