SHT21P SENSIRION, SHT21P Datasheet - Page 4

no-image

SHT21P

Manufacturer Part Number
SHT21P
Description
SENSOR, HUMIDITY & TEMP
Manufacturer
SENSIRION
Datasheet

Specifications of SHT21P

Humidity Range
0 - 100% RH
Sensor Output
Analogue - PWM Interface
Sensor Terminals
SMD
Response Time
8s
Supply Voltage Range
2.1V To 3.6V
Accuracy
2% RH
Supply Voltage
3VDC
Termination
RoHS Compliant
Capacitance
0µF
Rohs Compliant
Yes
Sensing Accuracy
2%
Operating Temperature Range
-40°C To +125°C
Msl
MSL 2 - 1 Year
Datasheet SHT21P
For solder paste printing a laser-cut, stainless steel stencil
with electro-polished trapezoidal walls and with 0.125mm
stencil thickness is recommended. For the I/O pads the
stencil apertures should be 0.1mm longer than PCB pads
and positioned with 0.1mm offset away from the centre of
the package. The die pad aperture should cover about 70
– 90% of the pad area – say up to 1.4mm x 2.3mm
centered on the thermal land area. It can also be split in
two openings.
Due to the low mounted height of the DFN, “no clean”
type 3 solder paste
purge during reflow.
Figure 7 Soldering profile according to JEDEC standard. T
260°C and t
150sec. Ramp-up/down speeds shall be < 5°C/sec.
It is important to note that the diced edge or side faces of
the I/O pads may oxidise over time, therefore a solder fillet
may or may not form. Hence there is no guarantee for
solder joint fillet heights of any kind.
For soldering SHT2x, standard reflow soldering ovens may
be used. The sensor is qualified to withstand soldering
profile according to IPC/JEDEC J-STD-020D with peak
temperatures at 260°C during up to 40sec for Pb-free
assembly in IR/Convection reflow ovens (see Figure 7).
For manual soldering contact time must be limited to 5
seconds at up to 350°C
IMPORTANT: After soldering, the devices should be
stored at >75%RH for at least 12h to allow the sensor
element to re-hydrate. Otherwise the sensor may read an
offset that slowly disappears if exposed to ambient
conditions. Alternatively the re-hydration process may be
performed at ambient conditions (>40%RH) during more
than 5 days.
In no case, neither after manual nor reflow soldering, a
board wash shall be applied. Therefore, and as mentioned
above, it is strongly recommended to use “no-clean” solder
paste. In case of applications with exposure of the sensor
to corrosive gases or condensed water (i.e. environments
9
the size range of 25 – 45 µm (powder type 42).
10
www.sensirion.com
Solder types are related to the solder particle size in the paste: Type 3 covers
260°C = 500°F, 350°C = 662°F
T
T
T
P
L
S
(max)
P
< 40sec for Pb-free assembly. T
preheating
9
is recommended as well as Nitrogen
10
.
critical zone
t
L
L
< 220°C and t
t
P
Time
Version 1.1 – May 2010
P
L
<=
<
with high relative humidity) the soldering pads shall be
sealed (e.g. conformal coating) to prevent loose contacts
or short cuts.
2.2
Moisture Sensitivity Level (MSL) is 2 according to
IPC/JEDEC J-STD-020D.1; hence storage time is limited
to one year after date of delivery.
It is of great importance to understand that a humidity
sensor is not a normal electronic component and needs to
be handled with care. Chemical vapors at high
concentration in combination with long exposure times
may offset the sensor reading.
For this reason it is recommended to store the sensors in
original packaging including the sealed ESD bag at
following conditions: Temperature shall be in the range of
10°C – 50°C and humidity at 20 – 60%RH (sensors that
are not stored in ESD bags). For sensors that have been
removed from the original packaging we recommend to
store them in ESD bags made of metal-in PE-HD
In manufacturing and transport the sensors shall be
prevented of high concentration of chemical solvents and
long exposure times. Out-gassing of glues, adhesive tapes
and stickers or out-gassing packaging material such as
bubble foils, foams, etc. shall be avoided. Manufacturing
area shall be well ventilated.
For more detailed information please consult the
document “Handling Instructions” or contact Sensirion.
2.3
As stated above extreme conditions or exposure to solvent
vapors may offset the sensor. The following reconditioning
procedure may bring the sensor back to calibration state:
Baking:
Re-Hydration:
2.4
Relative
temperature. Therefore, it is essential to keep humidity
sensors at the same temperature as the air of which the
relative humidity is to be measured. In case of testing or
qualification the reference sensor and test sensor must
show equal temperature to allow for comparing humidity
readings.
If the sensor shares a PCB with electronic components
that produce heat it should be mounted in a way that
prevents heat transfer or keeps it as low as possible.
Measures to reduce heat transfer can be ventilation,
reduction of copper layers between the sensor and the
11
12
For example, 3M antistatic bag, product “1910” with zipper.
75%RH can conveniently be generated with saturated NaCl solution.
100 – 105°C correspond to 212 – 221°F, 20 – 30°C correspond to 68 – 86°F
Storage Conditions and Handling Instructions
Reconditioning Procedure
Temperature Effects
humidity
100 – 105°C at < 5%RH for 10h
20 – 30°C at ~ 75%RH for 12h
reading
strongly
depends
11
12
.
.
4/9
on

Related parts for SHT21P