AT52BC6402AT-70CU Atmel, AT52BC6402AT-70CU Datasheet - Page 12

no-image

AT52BC6402AT-70CU

Manufacturer Part Number
AT52BC6402AT-70CU
Description
Manufacturer
Atmel
Datasheet

Specifications of AT52BC6402AT-70CU

Operating Supply Voltage (max)
3.1V
Operating Temperature (max)
85C
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant
Command Definition (Hex)
Notes:
12
Command Sequence
Read
Chip Erase
Plane Erase
Sector Erase
Word Program
Dual-Word Program
Enter Single-pulse Program
Mode
Single-pulse Word Program
Mode
Sector Softlock
Sector Unlock
Sector Hardlock
Erase/Program Suspend
Erase/Program Resume
Product ID Entry
Product ID Exit
Product ID Exit
Program Protection
Register – Block B
Lock Protection
Register – Block B
Status of Block B
Protection
Set Configuration Register
CFI Query
1. The DATA FORMAT in each bus cycle is as follows: I/O15 - I/O8 (Don’t Care); I/O7 - I/O0 (Hex). The ADDRESS FORMAT in each bus cycle
2. Since A11 is a Don’t Care, AAA can be replaced with 2AA.
3. Either one of the Product ID Exit commands can be used.
4. SA = sector address. Any word address within a sector can be used to designate the sector address (see pages 14 - 17 for details).
5. Once a sector is in the Hardlock protection mode, it cannot be disabled unless the chip is reset or power cycled.
6. PA is the plane address (A21 - A20).
7. During the fourth bus cycle, the manufacturer code is read from address PA+00000H, the device code is read from address PA+00001H,
8. The fast programming option enables the user to program two words in parallel only when V
9. If data bit D1 is “0”, block B is locked. If data bit D1 is “1”, block B can be reprogrammed.
10. The default state (after power-up) of the configuration register is “00”.
11. Any address within the user programmable register region. Please see “Protection Register Addressing Table” on page 13.
12. For the AT49BV6416, xxxx = 0000H. For the AT49BV6416T, xxxx = 3F80H.
13. For the AT49BV6416, xxxx = 0000H. For the AT49BV6416T, xxxx = 0F80H.
AT52BC6402A(T)
is as follows: A11 - A0 (Hex), A11 - A21 (Don’t Care).
and the data in the protection register is read from addresses 000081H - 000088H. PA (A21 - A20) must specify the same plane address as
specified in the third bus cycle.
the two words, D
(3)
(3)
(7)
(8)
Cycles
Bus
IN0
1
6
6
6
4
5
6
1
6
2
6
1
3
3
1
4
4
4
4
1
1
and D
Addr
Addr
PA
Addr
X55
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
IN1
xxx
xxx
(6)
, must only differ in address A0. This command should be used for manufacturing purpose only.
1st Bus
Cycle
D
Data
AA
AA
AA
D
AA
AA
AA
AA
AA
AA
AA
AA
B0
FX
AA
AA
AA
AA
30
98
(1)
OUT
IN
AAA
Addr
SA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
2nd Bus
(4)
(2)
Cycle
Data
55
55
55
55
55
55
55
70
55
55
55
55
55
55
55
PA+00555
Addr
555
555
555
555
555
555
555
555
555
555
555
555
555
3rd Bus
Cycle
Data
A0
A1
C0
C0
E0
80
80
80
80
80
80
90
F0
90
xxxx
xxxx80
xxxx80
Addr0
Addr
Addr
555
555
555
555
555
555
(12)
xxx
8x
(12)
(13)
4th Bus
Cycle
(11)
PP
= 12V. The addresses, Addr0 and Addr1, of
00/01
D
Data
D
OUT
AA
AA
AA
D
AA
AA
AA
D
X0
IN0
IN
IN
(10)
(9)
Addr1
Addr
AAA
AAA
AAA
AAA
AAA
AAA
5th Bus
Cycle
Data
D
55
55
55
55
55
55
IN1
3441B–STKD–11/04
SA
PA
SA
SA
Addr
555
555
(4)(5)
(6)
6th Bus
(4)
(4)
Cycle
Data
A0
10
20
30
40
60