COMMAND INPUTS
A simple command set is used to communicate with the HMR2300. These commands can be automated; or typed in
real-time while running communication software programs, such a windows hyperterminal.
Format
Output
Sample Rate
Set/Reset
Mode
Set/Reset
Pulse
Device ID
Baud Rate
Zero
Reading
Average
Readings
Re-Enter
Response
Query Setup
Default
Settings
Restore
Settings
Serial
Number
Software
Version
Hardware
Version
Write Enable
Store
Parameters
Too Many
Characters
Missing WE
Entry
(1) All inputs must be followed by a <cr> carriage return, or Enter, key. Either upper or lower case letters may be used. The device
ID (dd) is a decimal number between 00 and 99. Device ID = 99 is a global address for all units.
(2) The “¬” symbol is a carriage return (hex 0D). The “_” sign is a space (hex 20). The output response will be delayed from the
end of the carriage return of the input string by 2 msec (typ.), unless the command sent as a global device ID = 99.
Solid State Electronics Center • www.magneticsensors.com • (800) 323-8295 • Page 7
Command
*ddWE *ddA
*ddWE *ddB
*ddWE *ddR=nnn
*ddWE *ddTN
*ddWE *ddTF
*ddWE *ddT
*ddWE *ddID=nn
*99WE *99!BR=S
*99WE *99!BR=F
*ddWE *ddZN
*ddWE *ddZF
*ddWE *ddZR
*ddWE *ddVN
*ddWE *ddVF
*ddWE *ddV
*ddWE *ddY
*ddWE *ddN
*ddWE *ddD
*ddWE *ddRST
*ddWE
*ddWE *ddSP
Wrong Entry
Write Enable Off
Inputs
*ddP
*ddC
Esc
*dd]S
*dd]R
*dd]
*99ID=
*ddQ
*dd#
*ddF
*ddH
(1)
WE_OFF¬
ASCII_ON¬
BINARY_ON¬
{x, y, z reading}
{x, y, z stream}
{stream stops}
OK¬
S/R_ON¬
S/R_OFF¬
{Toggle}
SET¬
RST¬
{Toggle}
ID=_nn¬
OK¬
OK¬
BAUD_9600¬
OK¬
BAUD=_19,200¬
ZERO_ON¬
ZERO_OFF¬
{Toggle}
AVG_ON¬
AVG_OFF¬
{Toggle}
OK¬
OK¬
{See Desc.}
OK¬
BAUD=_9600¬
OK¬
BAUD=_9600¬
or
BAUD=_19,200¬
SER#_nnnn¬
S/W_vers:_
nnnn¬
H/W_vers:_
nnnn¬
OK¬
DONE¬
OK¬
Re-enter¬
Response
(2)
Bytes
7 or 28
7 or 8
8 or 9
7 or 8
62-72
10
14
14
14
14
16
22
27
19
...
9
0
3
7
8
4
4
4
7
3
8
9
7
8
3
3
3
8
9
7
(3)
ASCII – Output Readings in BCD ASCII Format (Default)
Binary – Output Readings in Signed 16-bit Bianary Format
P = Polled – Output a Single Sample (Default)
C = Continuous – Output Readings at Sample Rate
Escape Key – Stops Continuous Readings
Set Sample Rate to nnn Where:
Nnn = 10, 20, 25, 30, 40, 50, 60, 100, 123, or 154
Samples/sec (Default = 20)
S/R Mode: TN – ON = Auto S/R Pulses (Default)
*ddT Toggles Command (Default = On)
] Character – Single S/R: ]S -> SET = Set Pulse
Toggle Alternates Between Set and Reset Pulse
Read Device ID (Default = 00)
Set Device ID Where nn = 00 to 98
Set Baud Rate to 9600 bps (Default)
Set Baud Rate to 19,200 bps
Zero Reading Will Store and Use Current as a Negative
Offset so That the Output Reads Zero Field
*ddZR Toggles Command
The Average Reading for the Current Sample X(N) is:
Xavg=X(N)/2 + X(N-1)/4 + X(N-2)/8 + X(N-3)/16 + ...
*ddV Toggles Command
Turn the “Re-Enter” Error Response ON (*ddY) or OFF
(*ddN). OFF is Recommended for RS-485 (Default = ON)
Read Setup Parameters. Default: ASCII, POLLED, S/R
ON, ZERO OFF, AVG OFF, R ON, ID=00, 20 sps
Change All Command Parameter Settings to Factory
Default Values
Change All Command Parameter Settings to the Last User
Stored Values in the EEPROM
Output the HMR2300 Software Version Number
Output the HMR2300 Hardware Version Number
Activate a Write Enable. This is required before
commands: Set Device ID, Baud Rate, and Store
Parameters.
This writes all parameter settings to EEPROM. These
values will be automatically restored upon power-up.
A command was not entered properly or 10 characters
were typed after an asterisk (*) and before a <cr>.
This error response indicates that this instruction requires
a write enable command immediately before it.
Output the HMR2300 Serial Number
TF – OFF = Manual S/R Pulses
(8 bits, no parity, 1 stop bit)