HIH-5031-001S Honeywell, HIH-5031-001S Datasheet - Page 2

no-image

HIH-5031-001S

Manufacturer Part Number
HIH-5031-001S
Description
Board Mount Humidity Sensors HyCal Sensing Produc 3600 Series CMOS Sen
Manufacturer
Honeywell
Datasheets

Specifications of HIH-5031-001S

Rh Range
0 % to 100 %
Rh Accuracy
+/- 3 %
Output Type
Analog
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Supply Current
200 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Body Style
Rectangular
Current, Switching
500 μA
Function
Humidity
Mounting Type
Surface Mount
Primary Type
Humidity
Range, Measurement
0 to 100 % RH
Voltage, Supply
2.7 to 5.5 VDC
Lead Free Status / RoHS Status
Supplier Unconfirmed
Table 1. Performance Specifications (At 3.3 Vdc supply and 25 C [77 F] unless otherwise noted.)
2
Parameter
Interchangeability (first order curve)
Accuracy (best fit straight line) 11% RH to 89% RH
Hysteresis
Repeatability
Settling time
Response time (1/e in slow moving air)
Stability (at 50% RH in 5 years)
Voltage supply
Current supply
Voltage output (1st order curve fit)
Temperature compensation
Output voltage temp. coefficient at 50% RH, 3.3 V
Operating temperature
Operating humidity (HIH-5030)
Operating humidity (HIH-5031)
Storage temperature
Storage humidity
Specific Notes:
1. Includes stress outside of recommended operating zone.
2. Device is tested at 3.3 Vdc and 25 C.
3. Non-condensing environment. When liquid water falls on
4. Total accuracy including interchangeability is 3 %RH.
0% RH to 10% RH, 90% RH to 100% RH
11% RH to 89% RH
the humidity sensor die, output goes to a low rail condition
indicating no humidity.
www.honeywell.com/sensing
Minimum
-40[-40]
-50[-58]
2.7
-7
-3
-3
0
0
V
OUT
=(V
True RH = (Sensor RH)/(1.0546
General Notes:
SUPPLY
Sensor is ratiometric to supply voltage.
Extended exposure to >90 % RH causes a reversible shift
of 3 % RH.
Sensor is light sensitive. For best performance, shield
sensor from bright light.
See Figure 3.
See Figure 2.
See Figure 2.
See Figure 2.
Typical
)(0.00636(sensor RH) + 0.1515), typical at 25 C
200
-2
0.5
1.2
2
5
Maximum
125[257]
85[185]
500
100
100
5.5
+3
70
7
3
0.00216T), T in C
mV/ C
% RH
% RH
% RH
% RH
% RH
% RH
% RH
% RH
% RH
C [ F]
C[ F]
Unit
Vdc
ms
s
A
Specific
Note
3
3
4
1
2

Related parts for HIH-5031-001S