LSZ53U Honeywell, LSZ53U Datasheet - Page 135

Switch Hardware Limit Switch Receptacles for HDLS

LSZ53U

Manufacturer Part Number
LSZ53U
Description
Switch Hardware Limit Switch Receptacles for HDLS
Manufacturer
Honeywell
Datasheet

Specifications of LSZ53U

Lead Free Status / RoHS Status
Compliant
SA Series
The harsh duty SA pressure transducer has a water resistant, stainless steel
case for complete protection from harsh environments. Internal hermetic
sealing is used to provide measurement from absolute pressures (psia) or
pressures referenced to a sealed chamber (psis). Underwriters Laboratories
has approved the SA as a component in float and pressure-operated motor
controllers (File #E93356).
Approvals:
Supply voltage:
Signal conditioning:
Operating temperature range:
Compensated temperature range:
Port style:
Output type:
Termination type:
OPTIONS
UL Approval
MEASUREMENT TYPE
Absolute
Absolute
Absolute
Absolute
Gauge
Sealed Gauge
Sealed Gauge
Sealed Gauge
Sealed Gauge
CE Approval
MEASUREMENT TYPE
Absolute
Absolute
Excitation: Red
Common: Blk
Signal: Wht
0,91 m long (3 ft)
(case shield)
shielded cable
3 conductor
color coded
Bare
SA WITH CABLE
(1.56)
40,0
PRESSURE RANGE
0 psia to 15 psia
0 psia to 25 psia
0 psia to 50 psia
0 psia to 100 psia
0 psig to 15 psig
0 psis to 100 psis
0 psis to 200 psis
0 psis to 500 psis
0 psis to 3,000 psis
PRESSURE RANGE
0 psia to 25 psia
0 psia to 50 psia
(0.38)
10,0
0,91 m (3 ft) 3-conductor shielded cable
1/8-27 NPT
3/8-24 UNF (optional ≥100 PSI)
1/2 Hex for 1/8-27 NPT port
9/16 Hex for 3/8-24 UNF port
-55 °C to 105 °C (-48 °F to 221 °F)
-1 °C to 85 °C (30 °F to 185 °F)
Amplified compensated
www.honeywell.com/sensing
CE (*C1DE products)
(1.88)
UL (*C1D products)
48,0
9.0 Vdc to 24.0 Vdc
REFERENCE
SA015PA1C1D
SA025PA1C1D
SA050PA1C1D
SA100PA1C1D
SA015PG1C1D
SA100PS1C1D
SA200PS1C1D
SA500PS1C1D
SA03KPS1C1D
REFERENCE
SA025PA1C1DE
SA050PA1C1DE
1 Vdc to 6 Vdc
(0.75)
19,0
1/8-27 NPT
SR Series
The Model SR is intended for OEMs requiring a small pressure sensor with
high pressure capability and superior corrosion resistance. Constructed of
brazen assembly of 300 series stainless steels, the SR can tolerate a wide
variety of corrosive medial without risk of leaking. The SR’s design provide
high working pressures and high overload and burst pressures at no extra
cost.
Supply voltage:
Signal conditioning:
Operating temperature range:
Compensated temperature range:
Port style:
Output type:
Termination type:
OPTIONS
MEASUREMENT TYPE
Gauge
Gauge
Gauge
Gauge
Gauge
Gauge
Gauge
Gauge
Gauge
A
(0.748 / 0.746)
accuracy and may cause damage. The O-ring groove on 2000 psi unit is
CAUTION: Contact with sensing surface at bottom of cavity will affect
19,0 / 18,95 18,5
wider to accommodate a backup ring behind the O-ring.
1
4,3 max.
7,6 max.
P
0
(0.30)
(0.17)
1
e r
R
0
2
P (
5
a
0
s
0
(0.75)
5 -
n
1 -
S
s
0
g
u
) I
0
0
5
e
e r
0
0
0
3 .
3 .
B
PRESSURE RANGE (PSI)
15,0 max.
All dimensions in inches (mm).
(0.625)
o
1 (
7
7
5 .
5
5
e r
2
O-RING GROOVE
0
7 .
9 (
9 (
i D
0
PRESSURE RANGE
0 psig to 15 psig
0 psig to 25 psig
0 psig to 50 psig
0 psig to 100 psig
0 psig to 200 psig
0 psig to 300 psig
0 psig to 500 psig
0 psig to 1,000 psig
0 psig to 2,000 psig
) 0
5 .
5 .
. a
) 2
) 2
O
2
2
2
-
0 -
0 -
0 -
R
n i
1
1
1
2
0
0
g
4, 22 AWG
TINNED Cu SOLID WIRES
14,0 (0.55) LONG
19,5 max.
(0.766)
*
A
2 .
2 .
2 .
-40 °C to 100 °C (-40 °F to 212 °F)
S
D
PRESSURE SENSORS
1
1
1
e
e
l a
p
5 (
5 (
5 (
h t
n i
3 .
3 .
3 .
* *
g
) 3
) 3
) 3
0 °C to 75 °C (32 °F to 167 °F)
+ Excitation
- Excitation
4 - 22 AWG tinned Cu wires
- Signal
2 .
2 .
2 .
C
D
Unamplified compensated
2
2
2
a
e
5 (
5 (
5 (
i v
p
a
c
d
h t
5 .
5 .
5 .
y t
) 8
) 8
) 8
0 mV to 100 mV
REFERENCE
SR015PGTB
SR025PGTB
SR050PGTB
SR100PGTB
SR200PGTB
SR300PGTB
SR500PGTB
SR01KPGTB
SR02KPGTB
b
+ Signal
Capsule
5.0 Vdc
133

Related parts for LSZ53U