G2R24DC24 Omron, G2R24DC24 Datasheet - Page 4

Electromechanical Relay DPDT 4A 24VDC 1.1KOhm Through Hole

G2R24DC24

Manufacturer Part Number
G2R24DC24
Description
Electromechanical Relay DPDT 4A 24VDC 1.1KOhm Through Hole
Manufacturer
Omron
Type
Power Relayr
Datasheet

Specifications of G2R24DC24

Contact Arrangement
DPDT
Dc Coil Voltage
24 V
Coil Current
21.8 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
24V
Contact Form
2 Form C
Voltage Rating (vdc)
125V
Voltage Rating (vac)
380V
Dropout Volt (min)
3.6VDCV
Coil Resistance
1.1kohm
Pick-up Voltage (max)
16.8VDC
Maximum Power Rating
120W/1KVA
Operate Time
15ms
Contact Current Rating
4A
Contact Material
Silver
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
25.5mm
Product Depth (mm)
13.5mm
Product Length (mm)
29mm
Operating Temp Range
-40C to 70C
Pin Count
8
Mounting Style
Through Hole
Termination Style
PC Pin
Package / Case
DIP
Lead Free Status / Rohs Status
Compliant
Latching dual coil type - Set coil
Latching dual coil type - Reset coil
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
■ Characteristics
Note: Data shown are of initial value.
194
3
5
6
12
24
3
5
6
12
24
Item
Contact resistance
Operate (set) time
Release (reset) time
Bounce time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
Rated voltage
Rated voltage
(VDC)
(VDC)
2. The operating characteristics are measured at a coil temperature of 23°C (73°F).
Power PCB Relay
227
167
138
70.60
34.60
200
119
100
50
25
Rated current
Rated current
(mA)
(mA)
Operate
Release
Mechanical
Electrical
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
10.80
30
43.50
170
694
15
42
60
240
960
resistance
resistance
G2R
Coil
Coil
(Ω)
(Ω)
0.026
0.073
0.104
0.42
1.74
0.001
0.003
0.005
0.018
0.079
Armature
Armature
Non-latching
100 mΩ
15 ms. max.
AC: 10 ms max.; DC: 5 ms max.
---
---
18,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute across contacts of same pole
3,000 VAC, 50/60 Hz for 1 minute between contact sets, 2-pole non-latching
1,000 VAC, 50/60 Hz for 1 minute between set and reset coils of dual coil latching
10 to 55 Hz; 1.50 mm (0.06) double amplitude
10 to 55 Hz; 1.50 mm (0.06) double amplitude
1,000 m/s
200 m/s
100 m/s
-40 to 70°C (-40 to 158°F)
5% to 85% RH
10,000,000 operations min.
DC: 20,000,000 operations min.
(at 18,000 operations/hour)
100,000 operations min. (at 1,800 operations /hr) at rated load. See “Characteristics Data”
Approx. 17 g (0.60 oz.)
OFF
OFF
Coil inductance
Coil inductance
(ref. value) (H)
(ref. value) (H)
2
2
(approx. 20 G) when energized
(approx. 10 G) when de-energized
2
(approx. 100G)
0.052
0.146
0.208
0.83
3.43
0.002
0.006
0.009
0.036
0.148
Armature
Armature
ON
ON
70% max.
70% max.
Pick-up
voltage
Pick-up
voltage
% of rated voltage
% of rated voltage
70% max.
70% max.
Latching
20 ms max.
20 ms max.
Mean value approx. 3 ms
Mean value approx. 8 ms
500 m/s
200 m/s
100 m/s
10,000,000 operations min.
(at 18,000 operations/hour)
Approx. 17 g.
(Approx 20g for quick-connect type)
Dropout
Dropout
voltage
voltage
2
2
2
(approx. 50 G) at set (1-pole)
(approx 20G) at set (2-pole)
(approx. 10 G) at reset
110% max.
at 70°C
(158°F)
110% max.
at 70°C
(158°F)
Maximum
Maximum
voltage
voltage
Approx. 850
Approx. 600
consumption
consumption
Power
Power
(mW)
(mW)