OKI-T/36W-W40P-C Murata Power Solutions Inc, OKI-T/36W-W40P-C Datasheet
OKI-T/36W-W40P-C
Specifications of OKI-T/36W-W40P-C
Related parts for OKI-T/36W-W40P-C
OKI-T/36W-W40P-C Summary of contents
Page 1
... These converters also include under voltage lock out (UVLO), output short circuit protection, over- current and over temperature protections. These units are designed to meet all standard UL/EN/IEC 60950-1 safety certifi cations and RoHS- 6 hazardous substance compliance. Page +Vout Trim Common email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page ...
Page 2
... ORDERING GUIDE I OUT V (Amps Power OUT Root Model (Volts) max) (Watts) OKI-T/36W-W40P-C 5.021-15 OKI-T/36W-W40N-C 5.021-15 ➀ Dimensions are in inches (mm). ➁ Remote on/off polarity is negative. ➂ All specifications are at nominal line voltage, Vout = 5.021-15.5V and full load, +25 ˚C. unless otherwise noted. Output capacitors are 1 μF ceramic and 10 μF electrolytic in parallel. Input cap is 22 μF. See detailed specifications. ...
Page 3
... REF [8.64] 0.340 [1.52] [12.69] 0.060 0.500 REF [17.52] 0.690 RECOMMENDED PAD LAYOUT email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page PIN #1 Function On/Off Control Ground (Common) Trim +V OUT Third Angle Projection [11.9] 0.47 REF [1.52] 0.06 REF ...
Page 4
... V.to +40 Volts max min. to +Vin max. None. Install external fuse. Current-limited. Devices can withstand a sustained short circuit without damage. The outputs are not intended to accept appreciable reverse current. -55 to +125 ˚C. See soldering specifi cations email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page ...
Page 5
... Less than 3 ºC. per second Peak Temp. 235-260° C Reflow Zone Soaking Zone time above 217° C 45-75 sec 120 sec max Preheating Zone 240 sec max 90 120 150 180 210 240 270 Time (sec) email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page 300 ...
Page 6
... In order to minimize circuit errors and standardize tests between units, scope measurements should be made using BNC connectors or the probe ground should not exceed one half- inch and soldered directly to the test circuit. www.murata-ps.com CURRENT PROBE +INPUT C IN -INPUT email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page ...
Page 7
... Be aware too that there is a fi nite time in milliseconds (see Specifi cations) between the time of On/Off Control activation and stable, regulated output. This time will vary slightly with output load type and current and input conditions. www.murata-ps.com OKI-T/36W-W40 Series email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page ...
Page 8
... Install only enough OKI-T/36W-W40 Series Selectable Output 36-Watt DOSA-SMT DC/DC Converters capacitance to achieve noise objectives. Excess external capacitance may cause regulation problems, degraded transient response and possible oscilla- tion or instability. www.murata-ps.com email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page ...
Page 9
... OUT V = 19V 24V 40V IN 0.5 1 1.5 2 2.5 Load Curre nt (Amps) Maximum Current Temperature Derating at Sea Level (V = 24V 15V, transverse airfl ow) IN OUT 65 LFM 100 LFM 200 LFM 300 LFM Ambient Temperature (ºC) email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page 3 ...
Page 10
... V = 12V, transverse airfl ow) IN OUT 65 LFM 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (ºC) Maximum Current Temperature Derating at Sea Level (V = 24V 5V, transverse airfl ow) IN OUT 65 LFM Ambient Temperature (ºC) email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page ...
Page 11
... LFM 400 LFM Ambient Temperature (ºC) Output Ripple and Noise (Vin=24V, Vout=12V, Iout=3.23A, Cload=0, ScopeBW=100MHz) Step Load Transient Response (Vin=24V, Vout=12V, Cload=0, Iout=3A to 1.5A) www.murata-ps.com OKI-T/36W-W40 Series Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page ...
Page 12
... Angles ± 1˚ Components are shown for reference only. 101.6 4.00 (CORE) 13.00 REEL INFORMATION (400 UNITS PER REEL) email: sales@murata-ps.com 09 Feb 2011 MDC_OKI-T/36W-W40.A01 Page 6.86 0.270 Third Angle Projection 44.0 1.73 REF 13.00 .512 © 2011 Murata Power Solutions, Inc. ...