Page 1
... Miniature design with a 50-mm depth. • Incorporating a connector, thus saving wiring effort. • Connecting to OMRON's PLCs via dedicated PLC cables (sold separately). • Units and minus symbols are displayed (three- and four-digit model only). ...
Page 2
... Numerals and units M7F-4N1GT* Positive Numerals only M7F-4D1G Numerals and minus symbol M7F-4D1GF Numerals and units M7F-4D1GT* Positive Numerals only M7F-5D1R Positive Numerals only M7F-5D1G Compatibility with OMRON PLCs (Examples) Dynamic CS1W-OD211 output C200H-OD215/218/219 C500-OD213 × CQM1-OD213 × CS1W-OD212 ❍ C500-OD212 C200H-OD215 M7F ■ ...
Page 3
... Ideal for the Cable with connection of the M7F Crimp-style to devices Terminals incorporating screw terminals. Suitable Output Units: CS1W-OD211, CS1W-OD212, C200H-OD212, and C500-OD412 Appearance PLC M7F L OMRON's C500-CE243 OMRON's (Fujitsu's FCN-36@@040 XG4M-2030-T Series) Connection On the PLC M7F Connector Connector pin No. pin No. (Line A Line ...
Page 4
... X, Y, and Z directions Shock 2 Malfunction: 300 m/s resistance 3 times each in 6 directions and Z axes Degree of IEC IP40 (front panel only) protection Note: Impulse conditions: Rise time +10% max. Pulse width: 100 ns, 1 µs Frequency: 100 Hz Polarity: Positive or negative Cable: OMRON's G79-100C M7F 4 ...
Page 5
... B4 A4 symbol Input signals Negative Logic Static Input (M7F-@N@@@) 3 10 digit Terminal no. Terminal symbol Input signals Input signal digit 10 digit Input signal digit 10 digit Display condition 0 10 digit digit digit digit Display condition 0 10 digit digit digit digit M7F digit digit ...
Page 6
... The Unit has a function for blanking (i.e., turning OFF the display) to not display 0 when the leftmost digits are zero. When DP (decimal point) has been displayed using the DIP switch, the digits to the left of the decimal point display digit will be blank as shown in the following figure. Fourth ...
Page 7
... Power supply and output terminal Power supply 0-V output terminal (GND) 0 Displays the numeral or symbol corresponding to the binary code signal Designates the digit to be displayed. Each digit will maintain the previous 0 S0 (10 ) value when this signal is input ( ( ( (10 ) Power supply and output terminal ...
Page 8
... Power supply output into the PLC Signal input LED display elements Signal Positive Logic Input Method Input 57 kΩ Circuit Signal input 0.033 µF 10 kΩ Negative Logic Input Method 7 kΩ 29 kΩ Signal input 0.033 µF Dynamic Input Method ...
Page 9
External Connections Refer to Block Diagram on page 8 and Terminal Arrangement on page 7 for external connections for the M7F according to the signal input method. PLC Connections • Refer to your PLC operation manual before connecting the ...
Page 10
M7F-@N@@@ Static Negative Logic Input Model 1. Connected to C500-OD213 Output Unit PLC Termi- Terminal nal No. name PLC Output Power Unit DC power supply input supply (+) Power VDC supply (0 V) input Note: The ...
Page 11
... Transfers the third digit's data of word 005 to the first digit of word 101. Transfers the fourth digit's data of word 005 to the third digit of word 101. Transfers the first digit data of word 006 to the first digit of word 102 M7F 's display M7F ...
Page 12
... H Strobe input Data latch Data read Data latch ( ■ Operation Chart Dynamic Input Method (M7F-@D@@@) The following example shows the relationship between each input terminal and the display condition. (Example: 5-digit) Data contents 5 Data input signals ( Data read digit ...
Page 13
Dimensions Note: All units are in millimeters unless otherwise indicated. M7F-@@1@@ LED 10° The M7F-4@1@ is 7.8 illustrated. M7F-3@1@F M7F-3@1@T M7F-4@1@ M7F-4@1@F 14.2 M7F-4@1@T M7F-5D1 14.22 66.5 67 (13.5) 30.4 Panel Cutout (Single ...
Page 14
... DC power supply in order to protect the PLC from being damaged. • When using a controller other than the PLC or another company's PLC, be sure to check the terminal arrangement of the connector of the controller or the PLC. The terminal arrangement of OMRON's cables incorporating connectors corresponds to that of the PLC. Removing Color Plate There is a gap (with a width of approximately 1 mm) between the case and color plate on the left and right sides ...
Page 15
Attaching Color Plate Insert the projecting parts of the color plate into the square holes of the case to attach the color plate to the case. DIP Switch Settings The DIP switch can be set with the tip of a ...
Page 16
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...