6CFS1 Tyco Electronics, 6CFS1 Datasheet

MODULE POWER ENTRY SNAP 6A

6CFS1

Manufacturer Part Number
6CFS1
Description
MODULE POWER ENTRY SNAP 6A
Manufacturer
Tyco Electronics
Series
Cr
Type
IEC 320-C14 (Male Pins)r
Datasheets

Specifications of 6CFS1

Current
6A
Features
Switch, On/Off, Non-Illuminated
Filter Type
General Purpose
Fuse Drawer
Fuse Not Required
Mounting Type
Panel Mount, Snap-In
Termination Style
Quick Connect - .250" (6.3mm)
Voltage
250VAC
Gender
Receptacle
Voltage Rating
250VAC
Current Rating
6A
Connector Mounting
Snap-In
Contact Termination
Quick Connect
Connector Type
Filtered Power Entry
Filtered
Yes
Leakage Current
0.4 mA
Type Of Inlet
Power Entry (Filtered/Unfiltered)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
1-1609113-0
1-6609113-0
6CFS1
CCM1699
110
C Series
C Series
Two function power entry module combining a DPST switch
and an IEC 320 power line connector. Compact packaging
allows a smaller panel cutout with choice of snap-in or
flange mounting. Available with general purpose filtering (F
models - CFS, CFE), medical application filtering (H models
- CHS, CHE) or unfiltered (CS, CE). Terminals allow for easy
connection to any wiring scheme. Preconnected terminals
from line to switch are available (B Models - CBS, CBE) for
reducing OEM wiring time.
The medical versions (H models) are designed specifically
for health care applications. Their extremely low leakage
current allows compliance with UL544 and UL2601 as well
as CSA22.2 health care specifications for use with both
patient and non-patient care equipment. For more
information on UL544 or UL2601, see Appendix C.
Note: When using the models with an IEC connector,
remember that the leakage current of the companion line
cord, GA400, is more significant than that of the filter -
which may disqualify this line cord from use in patient care
applications.
Electrical Schematics
Catalog 1654001
Revised 04-06
UL Recognized
CSA Certified
VDE Approved
F Models (CFS, CFE)
H Models (CHS, CHE)
B Models (CBS, CBE)
Resistor location for reference only.
G
Note 1: Jumpers provided on CBS and CBE versions only.
Note 2: Location of optional filter
N
LINE
L
LINE
Note 1
Note 1
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Power On/Off
Note 2
Note 2
CORCOM Product Guide
Switch with IEC Connector Compact Size
LOAD
LOAD
L
G
N
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Specifications
Maximum leakage current, each line to ground: †
Hipot rating (one minute):
Operating frequency:
Rated voltage:
Operating voltages:
Switch:
Unfiltered Push-on Force:
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
F Models
0
0
0
H Models
0
0
0
Line-to-line in 50 ohm circuit
F Models
0
0
0
H Models
0
0
0
Current
Current
Rating
10A
10A
Rating
10A
10A
1A
3A
6A
1A
3A
6A
1A
3A
6A
1A
3A
6A
@120 VAC 60 Hz:
@250 VAC 50 Hz:
line-to-ground
line-to-line
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
0.05
0.05
CFS
10
16
1
1
1
1
2
1
2
2
1
8
9
4
4
1
0.15
0.15
26
16
11
21
14
10
6
3
6
6
7
6
5
5
4
4
49-89-6089-0
Frequency MHz
Frequency MHz
0.5
0.5
46
32
22
14
37
31
22
10
13
14
14
14
13
10
14
11
F Models
.25 mA
.40 mA
Double-insulated rated
Amp inrush capability.
48
36
27
18
44
32
23
15
28
23
27
23
29
22
20
19
1
1
for 10,000 operations
Applies to Filtered models only.
CS
www.corcom.com
www.tycoelectronics.com
46
43
36
27
26
26
19
11
62
65
46
42
38
36
31
32
5
5
115/230 VAC
at full load.
18 lb/80 N
2250 VDC
1450 VDC
50/60 Hz
H Models
250 VAC
10
47
48
41
33
21
24
18
11
10
67
65
48
44
42
34
33
37
2 µA
5 µA
30
46
50
50
42
10
14
13
30
42
67
58
62
26
36
37
38
9

Related parts for 6CFS1

6CFS1 Summary of contents

Page 1

CORCOM Product Guide Switch with IEC Connector Compact Size C Series UL Recognized CSA Certified VDE Approved C Series Two function power entry module combining a DPST switch and an IEC 320 power line connector. Compact packaging allows a smaller ...

Page 2

... CFS, CHS 1.23 B 31.24 CFE, CHE 1.74 44.2 Part Numbers 010CS1 010CE1 01CFS1 01CFE1 B 03CFS1 03CFE1 06CFS1 06CFE1 10CFS1 10CFE1 Recommended Panel Cutout Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 reference purposes only. CORCOM Prods: 1-847-680-7400 Specifications subject Germany: to change ...

Related keywords