143PC05DW Honeywell, 143PC05DW Datasheet - Page 11

Board Mount Pressure Sensors 100PC/200PC PRESSURE

143PC05DW

Manufacturer Part Number
143PC05DW
Description
Board Mount Pressure Sensors 100PC/200PC PRESSURE
Manufacturer
Honeywell
Datasheet

Specifications of 143PC05DW

Operating Pressure
+/- 5 psi
Pressure Type
Differential
Output Type
Amplified
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
7 V to 16 V
Supply Current
8 mA
Output Voltage
1 V to 6 V
Lead Free Status / RoHS Status
Compliant
AWM5000 Series - High flow
AWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing. They measure
flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25
inches H
possibilities due to orifice or bypass channel clogging.
The rugged plastic package has been designed to withstand common mode pressures up to 50 psi, and
the small sensing element allows 100 g of shock without compromising performance. The included
“AMP” compatible connector provides reliable connection in demanding applications.
Each AWM5000 sensor contains circuitry which performs amplification, linearization, temperature
compensation, and gas calibration. A 1 to 5 Vdc linear output is possible for all listings regardless of flow
range (5, 10, 15, or 20 SLPM) or calibration gas (nitrogen, carbon dioxide, nitrous oxide, or argon). All
calibration is performed by active laser.
Signal conditioning:
Port style:
FLOW/PRESSURE RANGE
0 SLPM to 5 SLPM (N
0 SLPM TO 10 SLPM (N
0 SLPM to 20 SLPM (CO
0 SLPM to 20 SLPM (N
AWM700 Series
AWM700 Series microbridge mass airflow sensors provide in-line flow measurement with a specially
designed bypass flow housing. The sensors measure flow as high as 200 standard liters per minute
(SLPM) while inducing a pressure drop of 1 inch H
capability in a small package.
Signal conditioning:
Port style:
FLOW/PRESSURE RANGE
+ 200 SLPM
2
O. The microbridge chip is in direct contact with the flow stream, greatly reducing error
2
2
calibration)
2
2
calibration)
calibration)
calibration)
2
O, typically. The AWM700 has a high flow range
www.honeywell.com/sensing
REFERENCE
AWM5101VN
AWM5102VN
AWM5104VC
AWM5104VN
REFERENCE
AWM720P1
Amplified (1 Vdc to 5 Vdc)
Amplified (1 Vdc to 5 Vdc)
Threaded, ¼¨ NPT
Tapered, 22 mm
CAUTION
PRODUCT DAMAGE
AWM Series Microbridge Mass Airflow Sensors
are not designed to sense liquid flow
and will be damaged by liquid flow
through the sensor.
Failure to comply with these
instructions could result in product
damage.
MASS AIRFLOW
11