C20F.0111 Schurter Inc, C20F.0111 Datasheet

MOD PWR ENTRY QC SNAP-IN PNL MT

C20F.0111

Manufacturer Part Number
C20F.0111
Description
MOD PWR ENTRY QC SNAP-IN PNL MT
Manufacturer
Schurter Inc
Series
C20Fr
Type
IEC 320-C20 (Male Pins)r
Datasheet

Specifications of C20F.0111

Current
20A
Features
Shielded
Filter Type
General Purpose
Fuse Drawer
Fuse Not Required
Mounting Type
Panel Mount, Snap-In
Termination Style
Quick Connect - .250" (6.3mm)
Voltage
250V
Gender
Plug
Voltage Rating
250VAC
Current Rating
20A
Connector Mounting
Panel
Contact Termination
Quick Connect
No. Of Outlets
1
Connector Type
Power Entry
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
486-1081
Power Entry Modules with Line Filter
Description
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
- 2 Functions:
Appliance Inlet Protection class I, Line filter in standard and medical
- Solder, quick connect or wires (stranded)
Approvals
- VDE Certificate Number: 104884
- UL File Number: E72928
- CSA File Number: 97784
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Impulse Withstand Voltage
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Screw-on mounting
from front side
IEC Appliance Inlet C20 with Filter, Front or Rear Side Mounting
side
version
70° C
C20
16 A @ Ta 40 °C / 250 VAC; 50 Hz
20 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N (Cy2)
> 2.7 kVDC between L/N-PE (Cy2)
Test voltage (2 sec)
> 2.5 kV between L-N (CX2)
> 4 kV between L-N (CX1)
> 5 kV between L/N-PE (Cy2)
voltage (1.2/50 μs)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder, quick connect or wires (stran-
ded)
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1 mm to 3 mm
Thermoplastic, black, UL 94V-0
Snap-in mounting
from front side
EMC Products
Characteristics
- Compact design with optimal shielding
Suitable for assembly in metal plated plastic housings
- Version with class X1 and X2 (standard version) capacitors
- Universal line filter for standard applications
Designed for standard and medical applications
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- 16A according to UL
- Capacity CX 330 nF
References
Weblinks
General Product Information, Approvals, RoHS, CHINA-RoHS, Mating
Connectors, e-Store, SCHURTER-Stock-Check, Distributor-Stock-
Check, Accessories, Wire Harness
Appliance-Inlet/-Outlet
Line Filter
MTBF
Screw-on mounting
from rear side
with wires (stranded)
www.schurter.com/pg06
C20 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class 1
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 3'000'000 h acc. to MIL-HB-217 F
Standard- or Medical-Filter
C20F


Related parts for C20F.0111

C20F.0111 Summary of contents

Page 1

Power Entry Modules with Line Filter IEC Appliance Inlet C20 with Filter, Front or Rear Side Mounting Screw-on mounting from front side C20 70° C Description - Panel Mount: Screw-on version from front or rear side, snap-in version from front side - 2 Functions: Appliance Inlet Protection class I, Line filter in standard and medical version - Solder, quick connect or wires (stranded) Approvals - VDE Certificate Number: 104884 - UL File Number: E72928 - CSA File Number: 97784 Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical ...

Page 2

C20F www.schurter.com/pg06 Dimensions Screw-on mounting from front side Solder terminal: identical outer dimensions Screw-on mounting from rear side with metal flange 0 Snap-in mounting from front side R2 30 Technical Data of ...

Page 3

... Quick connect terminals 6.3 x Screw Rear-Side Quick connect terminals 6.3 x Screw Rear-Side Solder terminals EMC Products C20F Capacitor Order Number X2 C20F.0101 X1 C20F.0103 X2 C20F.0001 X1 C20F.0003 X2 C20F.0221 X1 C20F.0223 X2 C20F.0121 X1 C20F.0123 X2 C20F.0021 X1 C20F.0023 X2 C20F.0111 X1 C20F.0113 X2 C20F.0011 X1 C20F.0013 X2 C20F.0102 X1 C20F.0104 X2 C20F.0002 X1 C20F.0004 X2 C20F.0222 X1 C20F.0224 X2 C20F.0122 X1 C20F.0124 X2 C20F.0022  ...

Page 4

C20F www.schurter.com/pg06 Rated Current Rated Current Filter-Type IEC [ Medical Version (M5 Medical Version (M5 Medical Version (M5 Medical Version (M5 Medical Version (M5 Medical Version ...

Page 5

Power Entry Modules with Line Filter Power CordOverview complete Power Cord with IEC Connector C19, Straight Power Cordfurther types toC20F Power Supply or Interconnection CordOverview complete Divers Power Supply and Interconnection Cords 16 A Power Supply or Interconnection Cordfurther types ...

Related keywords