FN284-1-06 Schaffner EMC Inc, FN284-1-06 Datasheet

MOD PWR INLET COMPACT FILTER 1A

FN284-1-06

Manufacturer Part Number
FN284-1-06
Description
MOD PWR INLET COMPACT FILTER 1A
Manufacturer
Schaffner EMC Inc
Series
FN 280r
Type
IEC 320-C16 (Male Pins)r
Datasheets

Specifications of FN284-1-06

Termination Style
Quick Connect - .250" (6.3mm)
Current
1A
Features
Fuse Holder, Switch On/Off Non-Illuminated
Filter Type
General Purpose
Fuse Drawer
Included
Mounting Type
Panel Mount, Screw Hole
Voltage
250VAC
Filtered
Yes
Product
Modules
Current Rating
1 A to 1.2 A
Voltage Rating
250 V
Contact Plating
None
Housing Material
Metal
Mounting Style
Flange
Operating Temperature Range
- 25 C to + 85 C
Flammability Rating
UL 94 V-2
Connector Type
IEC Inlet Filter
Capacitance, Cx
220
Capacitance, Cy
2.2
Current, Leakage
373 μA
Current, Rating
1 A
Cut Out, Panel
29 × 60 mm
Gender
Male
Inductance
7.5 mH
Mount Method
Rear
Number Of Poles
1 (Fuseholder), 2 (Line Switch)
Resistance
1000 Kilohms
Schaffner Part Number
284-904
Temperature, Operating
-25 to +85 °C
Termination
Solder/Spade
Thickness, Panel
0.8-3 mm
Version
Standard
Voltage, Rating
250 VAC
Connector Mounting
Panel
Contact Termination
Quick Connect
Leakage Current Max
373µA
Rohs Compliant
Yes
Capacitance
220nF
Inductance Min
7.5mH
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
VDE, SEV, SEMKO, UL, CSA
Capacitance X Type Capacitor
220nF
Termination Type
Faston Tab
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
284-904
817-1103
FN 284 - 1 -06

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FN284-1-06
Manufacturer:
SCHAFFNE
Quantity:
659
Technical specifications
Maximum continuous operating voltage:
Operating frequency:
Rated currents:
High potential test voltage:
Protection category:
Temperature range (operation and storage):
Design corresponding to:
Flammability corresponding to:
MTBF @ 40°C/230V (Mil-HB-217F):
Fuse holder:
Marking:
Rocker switch description:
Function:
Electrical specifications:
Mechanical life:
Switch ratings:
USA (UL) and Canada (C-UL):
Europe (ENEC):
*
The FN 280 power entry module combines
an IEC inlet, a mains filter with single or dual-
fuse holder and a 2-pole rocker switch in a
small form factor. Choosing FN 280 product
line brings you the rapid availability of a
standard filter associated with the necessary
safety acceptances. Standard IEC connector
filters are a practical solution helping you to
pass EMI system approval in a short time.
A wide selection on amperage ratings, fuse
options, mounting possibilities and filters for
medical applications are designed to offer
you the desired solution.
Compact filtered power entry module
Value in () relates to the inductive current charge: cos g = 0.65
n
n
n
n
n
n
250VAC, 50/60Hz
50 to 400Hz
1 to 10A @ 40°C max.
P –> E 2000VAC for 2 sec (standard types)
P –> E 2500VAC for 2 sec (B types)
P –> N 760VAC for 2 sec
IP40 according to IEC 60529
-25°C to +85°C (25/85/21)
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
UL 94V-2 or better
1,500,000 hours
1 or 2 fuses (Ø5 x 20mm)
2-pole, dark not illuminated
Marking I - 0
Inrush current 82A
6,000 on-off operations according to UL 1054, TV 5
10,000 on-off operations according to ENEC
50,000 cycles
10A, 125VAC; 10A, 250VAC; 1/3HP
10A (4A), 250VAC*
Features and benefits
n
n
n
n
n
Rated currents up to 10A
Single or dual-fuse holder
Fuses Ø5 x 20mm
2-pole rocker switch
General purpose application
Optional earth line choke (E type)
High conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal behavior.
Rear/front or snap-in mounting.
Single or dual-fuse holder.
2-pole rocker switch.
Custom-specific versions are available on
request.
max. 250V ~ (text is print. below fuse symbol)
IEC inlet filters
FN 280
Approvals
Typical electrical schematic
Standard types
N
E
P
E types
N
E
P
Typical applications
n
n
n
n
n
n
Line
Line
Portable electrical and electronic
equipment
Consumer goods
EDP and office equipment
Single-phase power supplies, switch-mode
power supplies
Test and measurement equipment
Medical equipment
Cx
Cx
R
R
2xL1
2xL1
L2
2xCy
2xCy
Load
Load
N‘
E‘
P‘
N‘
E‘
P‘

Related parts for FN284-1-06

FN284-1-06 Summary of contents

Page 1

... Standard IEC connector filters are a practical solution helping you to pass EMI system approval in a short time. A wide selection on amperage ratings, fuse options, mounting possibilities and filters for medical applications are designed to offer you the desired solution ...

Page 2

... FN 286B-1-06 1 (1.2) FN 286B-2-06 2 (2.4) FN 286B-4-06 4 (4.8) FN 286B-6-06 6 (7.2) FN 286B-10-06 10 (11.6) * Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. ** Filters are delivered without fuse. Inductance Capacitance Resistance [μA] [mH] [mH] [nF] [nF] 373 7 ...

Page 3

Components > FN 280 Product selector FN 28xx-yy-zz 06: Faston 6.3 x 0.8mm (spade/soldering 10: Rated current Blank: Standard version E: Optional earth line choke B: Medical version (with bleed resistor and without Y2-capacitor) 1: Flange mounting ...

Page 4

Components > FN 280 Mechanical data FN 281 / FN 282 A 6 285 / FN 286 A 6 ...

Related keywords